Trouble Shooting; Specification - BIELMEIER BHG 202 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

GB
Reduces formation of condensation on
ceilings, walls and windows (fig. 9) .
For best results, do not open windows and
doors when the unit is in use .
Reduces dampness of bookshelves and
cupboards (fig. 10) .
Open the door and put the dehumidifier
in front of the cupboard for it to operate
effectively .
?

tRouBLE SHootING

PRoBLEM
PoSSIBLE CAuSE
 Fan and compressor not
 No power or supply voltage
operating
too low
 Plug damaged or power
cord broken
 Compressor running but
 Motor failure
fan is not operating
 Fan working but
 Power supply voltage
compressor not operating
too low
 Within the 3-minute safety
period
 Compressor failure
 Unit could be in defrost
mode
20
use the condensed moisture: The water
collected in the tanks is free of dirt and chalk .
Hence, it is perfect for use in steam irons .
(fig. 9)
PRoBABLE SouLtIoN
 Check unit connection
to supply or contact the
power company
 Contact a qualified
electrician
 Contact a qualified
electrician
 Contact the power
company
 The return to normal after
3 minutes
 Contact a qualified
electrician
 This is normal .
PRoBLEM
 No dehumidification or
low performance
 Unit noise
 Unit frosted up
(fig. 10)
 Overflow of water

SPECIFICAtIoN

MoDEL:
Power source:
Power consumption:
Dehumidification capacoty (liter / day):
Running noise (dB):
Air flow rate:
Tank capacity – top:
Tank capacity – primary (bottom):
Compressor type:
Refrigerant:
Refrigerant charge:
Weight:
Dimensions (H x W x D):
PoSSIBLE CAuSE
PRoBABLE SouLtIoN
 Filter blocked
 Clean filter
 Gas leakage
 Contact a qualified
electrician
 Temperature & relative
 Normal
humidity too low
 Uneven surface
 Reposition unit on flat
surface
 Motor or compressor
 Contact a qualified
mountings loose
electrician
 Sound from water flow
 Normal, refrigerant enters
the heat exchanger (evapo-
ration in the cooling circuit)
 Filter blocked
 Clean filter
 Defrost mode not working
 Switch off
 Contact a qualified
electrician
 Water tank is leaking
 Contact a qualified
electrician
 Failure of primary tank float
 Contact a qualified
switch
electrician
BHG 202
AC 220 – 240 V / 50 Hz
365 W
20 liter / day (30°C, 80 % relative humidity)
52 dB (A)
approx . 144 m³/h
3,8 liters
1,2 liters
Rotary
R-134a CFC-free
170 g
14,2 kg
724 x 390 x 240 mm
GB
21