PCB LED BATTERY INDICATION STATUS
S.NO
LED Indication
1
Glows Green
2
Glows Amber
3
Blinks Amber
4
'Red ' Blinks 5
times and
Continuosly glow
5
'Red' Blinks for 5
times once & then
2 Blinks for every
4 Sec delay
PLEASE REFER TO THE BACK OF THE MANUAL FOR PICTORIAL INSTRUCTIONS
5
Voltage Level
Possible reasons for
this Indication
>24V
-
Between 23 and
-
24V
Between 21.6
-
and 23V
<21.6V
Occurance of Low
Voltage
Cut-OFF
-
1.) Voltage Below 24V
2.) Motor TOP (Thermal
Overload Protector) is
actived.
3.) Motor Fault (Short &
Open)
4.) PCB faulty
Machine Status
Remedy
Machine operates
-
normally
Machine operates
-
normally
Machine operates
-
normally, however
approaching cutoff.
Machine is not running
Step 1.) Charge the battery for about 5 hours
with 2A charger.
Step 2.) Check if the same RED indicator
appears. If so, measure whether the battery
voltage is >26V . If battery voltage is >26V then
there might be a fault in the PCB. Change the
PCB and check again.
Step 3.) If the battery voltage is <26V after
charging , then repeat Step 1. If the battery
voltage is still <26V, then change the Battery.
Machine is not running
Step 1.) Charge the battery for about 5 hours
with 2A charger. Then try again.
Machine is not running
Step 2.) Wait for 1 hour, to allow the motor
temperature to reach room temperature.
ThentTry again.
Machine is not running
Step 3.) Ensure the connections of the Motor
are okay. Then try again.
If the issue still remains, take a new motor and
connect it to the PCB and check whether it
runs. (Be careful during the motor test because
there are rotating parts.)
Machine is not running
Step 4.) If the problem persists after the above
3 steps, then change the PCB and check again.
10-18