TECHNICAL SPECIFICATIONS

Model No.
Measurement range
Measuring Accuracy
Laser type
Laser class
Single-mode measurement
Continuous-mode measurement m, ft, in
Area measurement
Volume measurement
Laser point
Operating temperature
Storage temperature
Laser auto switch off
Instrument auto switch off
Battery
Weight (Without Batteries)
Dimensions
* Maximum deviation error or shorter range can occur
when laser exposed to bright sunlight, operated
across very rough or minimal reflective surface, or
used during extreme temperature conditions.
** When measuring within 10 m, measurement
accuracy is ± 2.0 mm; more than 10 m, measurement
accuracy is calculated as follows: ±2.0 mm± 0.05*
(D-10) (D: Measuring Distance, Unit: m).
DESCRIPTION
The numbers in the text refer to the diagrams on
page 2-3.
Fig. A
1. Display
2. Switch on / measure button
3. Function / measurement reference
4. Clear / switch off button
5. Reception lens
6. Laser beam outlet
WWW.VONROC.COM
Fig. B
7. Battery cover
LD501DC
0.15m-30m
Fig. C
8. Laser on
± 2mm
9. Continuous- / single mode
620 ~ 690 nm
10. Historical readings
II (<mW) acc.
11. Current reading
To EN60825-1: 2014;
12. Battery status
13. Hardware error
m, ft, in
14. Area / volume
15. Unit
m², ft², in²
3. ASSEMBLY
(automatic calculation)
m³, ft³, in³
Inserting / Replacing the Batteries (Fig. B)
(automatic calculation)
1. Remove the battery compartment cover (7).
Yes
2. lnsert batteries with correct polarity according
0~40 °C
3. Close the battery compartment cover (7).
-20~65 °C
Yes, after 30s
4. OPERATION
Yes, after 180s
2x 1.5V type LR03 AAA
(alkaline)
64 g
100 x 40 x 24 mm
Check the device:
• Make sure all parts are fitted on the machine
• Check whether there are any visible defects:
Switch on and off (Fig. A+C)
Hold down the measure button (2) to switch on the
Equipment. Equipment will always start in the default
reference setting of single measurement mode (9).
Hold down the switch off button (4) to switch off
the equipment.
Automatically switch off
The laser will be switched off automatically after
30 seconds and the equipment will be powered off
after 3 minutes of inactivity.
Clear button (Fig. A)
Press clear button (4) to clear the last command or
displayed data.
to battery cover indications.
WARNING! Danger of injury due to defective
components! The product must only be put
into operation if no defects are found.
Ensure that any defective parts are
replaced before the product is used again.
firmly.
broken parts, cracks, etc.