Trouble Shooting - Mitsubishi Electric M Série Manuel D'utilisation

Masquer les pouces Voir aussi pour M Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Trouble Shooting

Having trouble?
Air conditioner does not heat or cool well.
When heating operation starts, warm air does not blow from the indoor
unit soon.
During heating mode, the air conditioner stops before the set room tem-
perature is reached.
When the air ow direction is changed, the vanes always move up and
down past the set position before nally stopping at the position.
A owing water sound or occasional hissing sound is heard.
A cracking or creaking sound is heard.
The room has an unpleasant odor.
A white mist or vapor is emitted from the indoor unit.
Water or vapor is emitted from the outdoor unit.
The operation indicator does not appear in the wired remote controller
display. (*1)
"
" appears in the wired remote controller display. (*1)
When restarting the air conditioner soon after stopping it, it does not
operate even though the ON/OFF button is pressed.
Air conditioner operates without the ON/OFF button being pressed. (*1)
Air conditioner stops without the ON/OFF button being pressed. (*1)
Wired remote controller timer operation cannot be set. (*1)
"PLEASE WAIT" appears in the wired remote controller display. (*1)
An error code appears in the remote controller display.
Draining water or motor rotation sound is heard.
The fan speed changes in spite of not changing the setting.
*1: Only for wired remote controller
Here is the solution. (Unit is operating normally.)
Clean the lter. (Air ow is reduced when the lter is dirty or clogged.)
Check the temperature adjustment and adjust the set temperature.
Make sure that there is plenty of space around the outdoor unit. Is the
indoor unit air intake or outlet blocked?
Has a door or window been left open?
Warm air does not blow until the indoor unit has suf ciently warmed up.
When the outdoor temperature is low and the humidity is high, frost
may form on the outdoor unit. If this occurs, the outdoor unit performs a
defrosting operation. Normal operation should begin after approximately
10 minutes.
When the air ow direction is changed, the vanes move to the set posi-
tion after detecting the base position.
These sounds can be heard when refrigerant is owing in the air con-
ditioner or when the refrigerant ow is changing.
These sounds can be heard when parts rub against each due to expan-
sion and contraction from temperature changes.
The indoor unit draws in air that contains gases produced from the walls,
carpeting, and furniture as well as odors trapped in clothing, and then
blows this air back into the room.
If the indoor temperature and the humidity are high, this condition may
occur when operation starts.
During defrosting mode, cool air ow may blow down and appear like a
mist.
During cooling mode, water may form and drip from the cool pipes and
joints.
During heating mode, water may form and drip from the heat exchanger.
During defrosting mode, water on the heat exchanger evaporates and
water vapor may be emitted.
Turn on the power switch. " " will appear in the wired remote controller
display.
During central control, "
" appears in the wired remote controller display
and air conditioner operation cannot be started or stopped using the
wired remote controller.
Wait approximately three minutes.
(Operation has stopped to protect the air conditioner.)
Is the on timer set?
Press the ON/OFF button to stop operation.
Is the air conditioner connected to a central wired remote controller?
Consult the concerned people who control the air conditioner.
Does "
" appear in the wired remote controller display?
Consult the concerned people who control the air conditioner.
Has the auto recovery feature from power failures been set?
Press the ON/OFF button to stop operation.
Is the off timer set?
Press the ON/OFF button to restart operation.
Is the air conditioner connected to a central wired remote controller?
Consult the concerned people who control the air conditioner.
Does "
" appear in the wired remote controller display?
Consult the concerned people who control the air conditioner.
Are timer settings invalid?
WEEKLY
If the timer can be set,
,
the wired remote controller display.
The initial settings are being performed. Wait approximately 3 minutes.
The protection devices have operated to protect the air conditioner.
Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure
to provide the dealer with the model name and information that appeared
in the remote controller display.
When cooling operation stops, the drain pump operates and then stops.
Wait approximately 3 minutes.
Not to blow out cold air at the beginning of heating operation, the air
conditioner automatically adjusts the fan speed gradually from lower to
the set speed. It also adjust its fan speed to protect the fan motor when
return air temperature or fan speed excessively rises.
SIMPLE
AUTO OFF
, or
appears in
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mvz-a12 aa4Mvz-a18 aa4Mvz-a24 aa4Mvz-a30 aa4Mvz-a36 aa4

Table des Matières