EN INSTRUCTIONS FOR INSTALLATION
TECHNICAL FEATURES
– Rated voltage: 230 V - 50/60 Hz
– Airflow: 80 m3/h
– IP34
– Installation in bathroom zone 2
– Electrical insulation class II
– Double voltage shaver socket (115/230 V)
– Adjustable drying settings with variable switch
– Flexible : 45 cm lenght, extendable up to 1.30 m,
external diameter: 44 mm; internal diameter: 34.5 mm
INSTALLATION
To connect a diode, switch off before connecting the power.
The switching contact distance is > 3 mm.
1. This appliance must be properly installed on the wall before being
used.
2. Bathroom installation is permitted in areas 2 and 3.
3. As in figure 2, drill three 6 mm diameter holes, and then insert the
attached stoples into these holes.
4. Fix the hanger with the attached screws (figure 2) and then hang
the whole unite to the wall. To remove the unite, push the hook under
the hanger and then lift the air dryer itself.
4
COMPONENTS
1. Control knob
2. Socket window
3. Sockets
4. Switch
5. Seal board
6. Stopple
7. Handle
– Patented handle to facilitate
hairdressing
– 550W – 1,000 W power, adjustable
through controller
– 15-minute safety timer
Figure 2
8. Stopple
9. Hanger
10. Screw
5. To connect the internal supply cord
(figure 3), remove the stopple (spare
parte 6) and the screw (spare part 11),
open the seal board (spare part 5), take
out the internal cord from the incoming
hole (spare part 13) and fix it to the
connecting terminal.
6. To disassemble the draught hose,
hold the hose with one hand and with
the other hand hold the ball tie-in, then
twist them to unfasten (see figure 2).
USE
1. Connect the power and lift the handle to start the dryer. Rotate
the knob clockwise for a stronger blow and higher temperature, and
counterclockwise to get a milder blow at a lower temperature. Put
the handle back on its hanger to stop the dryer.
2. After 15 minutes of continuous use, the dryer stops automatically.
If you place the handle on its hanger for 2 seconds and lift it again,
the unit restarts.
SPECIFICATIONS
Rated voltage: 220 – 240 V ≈
Rated frequency: 50 Hz
Rated power: 1000 W
Rated currency: 4.4 A
Waterproof level: IP34
Shock Protection:
ELECTRICAL INSTALLATION
For additional protection, the installation of a residual current device
(RCD) having a rated residual operating current not exceeding 30 mA
is advisable in the electric circuit supplying the bathroom. Ask your
installer for advice.
NOTES
1. If the wire is damaged or in case of malfunction, stop the unit
immediately and contact the manufacturer or a qualified electrician.
2. Do not hold the disassembled appliance by the supply cord.
3. Do not either disconnect the appliance with wet hands or force
the supply cord.
4. The hot air outlet must not be blocked with any kind of items,
such as magazines, towels, curtains, etc.
5. The appliance can only be used with the rated voltage and
frequency.
6. Do not splash the unit with water.
Figure 3
6. Stopple
11. Screw
5. Seal board
12. Connecting terminal
13. Incoming hole