Electrical connection
Electrical connection must only be carried out by
professional personnel trained and authorised for this.
...E+HFS
N
L
L'
To switch more than 2 luminaires via the sensor luminaire,
a power contactor has to be connected downstream over the
switching output (L').
...E+HFS
N
L
L'
14
L
N
...E
N
L
L
N
Technical data
Wattage
Idle current (standby)
Sensor
Sensor principle
Frequency range
Radiated power
Detection field
Range
Detection angle
Motion detection
Settable functions
Sensitivity
Hold time
Brightness levels
Operating conditions
Mounting height
< 1 W
HF motion detector
5,8 GHz +/- 75 MHz
< 1 mW
up to 8 m (with 100% sensi-
tivity, frontal, sensor without
cover)
ca 120°
0,3 ... 3 m/sec. (1 ... 10 km/h)
steplessly from 20 - 100%
steplessly from 20 - 300 sec.
(2sec. test model)
steplessly from 5 - 1000 lux
max. 4.0 m (ceiling mounting)
max. 2.7 m (wall mounting)
15