1/4" and 5/16" nut driver
(recommended)
Utility knife
Level

Parts supplied:

Leveling legs (4)
Cable ties (2)
Parts package is located in dryer drum. Check that all parts
are included.
NOTE: Do not use leveling legs supplied with dryer if installing
with a pedestal or a stack kit.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be
at least 4 ft. (1.22 m) long. The wires that connect to
the dryer must end in ring terminals or spade terminals
with upturned ends.
A UL listed strain relief.
Additional Accessories:
Refer to your Use and Care Guide for information about
accessories available for your dryer.
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
Tape measure
Pliers
6' (1829 mm) drain
hose with couplers
(Not supplied with dryer)

Location Requirements

Check code requirements. Some codes limit, or do not permit,
installing dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
You will need:
A separate 30 amp circuit.
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer. See
"Electrical Requirements."
Floor must support dryer weight of 200 lbs. (90.7 kg). Also
consider weight of companion appliance.
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If forward slope is greater than 1" (25 mm), water could
run out from front of filter. Install Extended Dryer Feet Kit, Part
Number 279810. If not level, clothes may not tumble properly
and automatic sensor cycles may not operate correctly.
For garage installation, place dryer at least 18" (460 mm)
above floor. If using a pedestal, you will need 18" (460 mm)
to bottom of dryer.
The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather.
IMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
40° F (4° C). Lower temperatures may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
DRYER DIMENSIONS
Front view:
38
/
" Min.
3
4
(984 mm)
39" Max.
(990 mm)
27"
(686 mm)
3

Publicité

Table des Matières
loading