TROUBLESHOOTING
Emergencies
Possible cause
Gas leaking from
Damaged hose.
cracked/cut/burned
hose
Gas leaking from LP
Mechanical failure due to resting or
tank
mishandling.
Gas leaking from LP
Failure or tank valve from mishandling
tank valve
or mechanical failure.
Gas leaking
Improper installation, connection not
between LP tank
tight, failure of rubber seal.
and regulator
connection
Fire coming
Fire in burner tube section of burner
through control
due to partial blockage.
panel
Troubleshooting:
Possible cause
Problem
Grease fire
Too much grease buildup in burner
or continuous
area.
excessive flames
above cooking
surface
Burner will not light
Gas issues
using ignitor
1.Trying to light wrong burner.
2. Burner not engaged with control
valve.
3. Obstruction in burner.
4. No gas flow.
5. Vapor lock at coupling nut to
LP tank.
6. Coupling nut ad LP tank valve not
fully connected.
Burner will not light
Electrical issues:
using ignitor
1. Electrode cracked or broken;"
sparks at crack."
2. Electrode tip not in proper position
3. Wire and/or electrode covered with
cooking residue.
4. Wires are loose or disconnected.
5. Wires are shorting (sparking)
between igitor and electrode.
6. Push button sticks at bottom
sparking between ignitor and
electrode.
Prevention/ Solution
Turn off gas at LP tank, if hoes is cut or
cracked, replace hose.See LP tank lead
test and connection regulator to the LP
tank.
Turn off LP tank valve.
Turn off LP tank valve. Return LP tank
to gas supplier.
Turn off LP tank valve, remove
regulator from cylinder and visually
inspect rubber seal for damage, see LP
tank test and connection regulator to
the LP tank.
Turn off control knobs and LP tank
valve. After fire is out and grill is cold,
remove burner and inspect for spider
nests or rust. see natural hazard and
cleaning the burner assembly pages.
Prevention/ Solution
Turn off LP Tank. Leave lid open
to allow flames to die down. After
cooling, clean food particles and excess
grease from inside firebox area, grease
cup/pan/tray, and other surfaces.
1. See instructions on control panel
and section in the Usage Methods.
2. Make sure valve are positioned
inside of burner tubes.
3. Ensure burner tubes are not
obstructed with spider webs or other
matted, see cleaning section of use
and care.
4. Make sure LP tank is not empty. If
LP tank is not empty, refer to
"sudden drop in gas flow.
5. Turn off knobs and disconnect
coupling nut from LP tank.
Reconnect and retry.
6. Turn the coupling nut approximately.
1. Replace electrode.
2. Tip of electrode should be pointing
toward port hole in burner. The
distance should be 1/8" to 3/16".
Adjust if necessary.
3. Clean wire and or electrode with
rubbing alcohol and clean swab.
4. Reconnect wires or replace
electrode/wire assembly.
5. Replace ignitor wire.
6. Replace ignitor.
7. Inspect wire insulation and proper
connection. Replace wires if
insulation is broken.
4