String format
YD:BANK [0..252]
YD:OFF <1..28>
YD:ON <1..28>
YD:TOGGLE <1..28>
YD:CHANNEL [OFF |
0..28]
YD:MARETRON [OFF
| ON]
YD:CZONE
[ON|OFF|AUTO]
YD:ENGINE [ANY |
0..252]
YD:SUPPRESS
[1..100000]
Examples
Digital switching (DS) mode commands
YD:BANK 0
YD:OFF 1
YD:ON 2
YD:TOGGLE 2
YD:CHANNEL 3
YD:MARETRON OFF
YD:CZONE ON
YD:CZONE AUTO
YD:CZONE OFF
YD:CZONE
Engine mode commands
YD:ENGINE ANY
YD:SUPPRESS 3600
— 20 —
Description
Sets the bank number, factory setting 0.
These commands change the state of the
specified channel.
Sets the channel number (event) which will
be activated by pressing of button. If 0 or
OFF value is specified, the button will only
deactivate events.
Turns on or off compatibility mode with
Maretron equipment.
Factory setting: AUTO. Activates features
required to control loads from chart plotters
with CZone support. See Section VI for details.
Selects associated engine. The port or single
engine is identified as 0, the next has number 1.
Factory setting is ANY.
The button press suppress the active event
for specified number of seconds. Factory
setting is 30.
Table 1 continued