Table of burner and nozzle specifications
GB
Table 1
BURNER
. 3 Rapid
. 2 Semi-rapid
. 1 Auxiliary
. 4 Triple Ring
Gas oven
Supply pressure
*
At 15°C and 1013 mbar - dry gas
Propane G31
Butane G30
Methane G20
Start-up and use
Using the hob
Lighting the burners
For each BURNER knob there is a complete ring showing
the strength of the flame for the relevant burner.
To light one of the burners on the hob:
1. Bring a flame or gas lighter close to the burner.
2. Press the BURNER knob and turn it in an anticlockwise
direction so that it is pointing to the maximum flame setting
.
3. Adjust the intensity of the flame to the desired level by
turning the BURNER knob in an anticlockwise direction.
This may be the minimum setting , the maximum setting
or any position in between the two.
position until the burner is lit. The burner might be extinguished
when the knob is released. If this occurs, repeat the process,
holding the knob down for a longer period of time.
22
Diameter
Heating
(mm)
power
kW (H.s.*)
Nomin.
Red.
100
0
3.00
75
5
1.65
55
1.00
130
3.25
4.00
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
P.C.S. = 50.37 MJ/Kg
P.C.S. = 49.47 MJ/Kg
P.C.S. = 37.78 MJ/m
3
The appliance is fitted with an
electronic lighting device which is
integrated into the knob. Simply light
the desired burner by turning the
corresponding knob in an anti-
clockwise direction, until it is aligned
with the large flame symbol, press
it all the way in to activate the
electronic ignition and hold it in that
Liquid gas
By-pass
Nozzle
1/100
1/100
(mm)
(mm)
0.7
40
86
0.4
30
64
0.4
30
50
1.3
57
91
0.8
45
95
! If the flame is accidentally extinguished, switch off the burner
and wait for at least 1 minute before attempting to relight it.
If the appliance is equipped with a flame failure safety device*,
press and hold the BURNER knob for approximately 2-3
seconds to keep the flame alight and to activate the device.
To switch the burner off, turn the knob until it reaches the
●
stop position
.
Practical advice on using the burners
For the burners to work in the most efficient way possible and
to save on the amount of gas consumed, it is recommended
that only pans which have a lid and a flat base are used.
They should also be suited to the size of the burner.
Burner
Fast (R)
Semi Fast (S)
Auxiliary (A)
Triple Crown (TC)
! Make sure the pans do not overlap the edges of the hob
while it is being used.
Natural gas
Flow *
Nozzle
g/h
1/100
G30
G31
(mm)
218
214
116
120
118
96
73
71
71
236
232
124
291
286
142
28-30
37
20
25
35
45
Ø Cookware Diameter (cm)
24 - 26
16 - 22
10 - 14
24 - 26
Flow *
l/h
G20
286
157
95
309
381
20
17
25