ELECTRICAL
NOTE: Ensure the electrical supply matches the kettle's requirements as stated on the rating
label.
This kettle is built to comply with CE standards. Many local codes exist, and it is the responsibility
of the owner and installer to comply with these codes.
NOTE: Maximum voltage for LVD is 440 volts for CE marked appliances.
Remove the four screws securing the console cover and remove the cover. A wiring diagram is
affixed to the underside of the cover. Feed permanent copper wiring through the cut-out in the
rear or bottom of the console, and fasten to the three connection terminal block, which is mounted
on the top of the console's control panel. Be sure to connect the ground wire to the separate
ground terminal connector (ground lug). Replace console cover and secure it with the four
screws.
3
RED
YELLOW
BLACK
The kettle is wired for 3-phase operation at the factory. For single phase operation, rewire the
terminal block to that shown in the above diagram.
1
RED
YELLOW
BLACK
L1 L2 L3
L1
L2

Publicité