EN - DOL 25 SENSOR TECHNICAL USER'S GUIDE
Figure 9
TECHNICAL DATA
Supply voltage (Ue)
Supply voltage (Ub)
Max. ripple
Rated current (Ie)
Voltage drop, output ON
Output function
No-load supply current
Time delay at start-up
Time delay ON
Time delay OFF
Temperature, operation
Temperature, storage
Protection class
Approvals
Operating distance (Sn) adjustable
Effective operating distance (Sa)
Repetition accuracy (R)
Hysteresis (H)
MAINTENANCE
INSTRUCTIONS
No maintenance is required. However, it may be necessary to clean around the sensor, if it is placed in a dirty
environment
Dol Sensors
Hedelund 4, Glyngøre
Sensor dimensions, Figure 9:
Cable length
Conductor dimensions
Conductor colours
Brown
Black
White
Blue
Conductor colours and pin numbers are according to
IEC60947-5-2.
DOL 25 PNP/NPN
10 – 36 V DC
NC and NO
< 100 mS
< 100 mS
0-600 sec.
-20 - +70 ºC
-30 - +80 ºC
CE and C-UL
Ø18 mm
Non-flushed
0-10 mm
7870 Roslev
Denmark
Tel. +45 72 17 55 55
4 x 0.26 mm
M12 sensor plug
V+
NO output
NC output
V-
10 %
500 mA
< 2.5 V
< 10 V AC RMS
< 6 mA
IP67
Ø30 mm
Flushed
Non-flushed
0-5 mm
0-20 mm
0 ≤ Sa ≤ 0.8* Sn mm
5 %
< 0.15* Sn mm
Fax +45 72 17 59 59
2 m
2
(AWG22)
1. V+
2. NC output
3. V-
4. NO output
DOL 25 SCR
20-250 V AC
300 mA
NC or NO
< 100 mS
< 100 mS
0-600 sec.
-20 - +70 ºC
-30 - +80 ºC
IP67
CE and C-UL
Flushed
0-10 mm
www.dol-sensors.com