- One beep is emitted to confirm programming.
- The Green LED is lighting up during 1 second.
3. Disconnect the purple cable with the black cable:
Two beeps are emitted to confirm exit
from programming.
F] PROGRAMMING CENTAUR OR STANDARD MODE
1. Enter in programming*.
2. Press A4 to select the mode:
- One beep is emitted.
- The Green LED is lighting up during 1 second.
- Press 0 for a Centaur mode or press 1
for a Standard mode.
- One beep is emitted to confirm programming.
- The Green LED is lighting up during 1 second.
3. Disconnect the purple cable with the black cable:
Two beeps are emitted to confirm exit
from programming.
G] DECIMAL OR HEXADECIMAL MODE
Decimal or hexadecimal mode affects
only the pin code output format.
1. Enter in programming mode*.
2. Press A5 to enter in the mode
setting menu:
- One beep is emitted.
- The Green LED is lighting up during 1 second.
- Press 0 for a decimal mode, press 1
for a hexadecimal mode.
- One beep is emitted to confirm programming.
- The Green LED is lighting up during 1 second.
9] 26-BIT WIEGAND FORMAT
Chronograms
\DATA1
\CLOCK
\DATA0
* Refer to the chapter «Entry in programming».
/Proximity reader - Wiegand
®
A4
A5
0 logic
50
2ms
μs
3. Disconnect the purple cable with the black cable:
Two beeps are emitted to confirm exit
from programming.
H] AUDIBLE SIGNAL
1. Enter in programming*.
2. Press A6:
- One beep is emitted.
- The Green LED is lighting up during 1 second.
- Press 0 to disable the audible signal.
- Press 1 to enable the audible signal.
- One beep is emitted to confirm programming.
- The Green LED is lighting up during 1 second.
3. Disconnect the purple cable with the black cable:
Two beeps are emitted to confirm exit
from programming.
I] EXTERNAL CONTROL OF THE LED & BUzzER
The buzzer can be activated from an external input.
The control is done with a logic signal on the input.
Buzzer + LED Off
OV
Centaur Mode
LED off. One beep is emitted + Orange LED when
the code is entering. The Buzzer and LED intputs
are activated.
Standard Mode
LED off. The Buzzer and LED intputs are activated.
1 logic
50
2ms
μs
A6
Buzzer + LED On
Buzzer + LED Off