English
Backflow: the alarm is set when backflow is greater than an R programmable value,
generally a few tens of litres.
Battery lifetime: the alarm is set when there is less than 1 year of battery autonomy.
Alarm reset: the alarms are reset after a programmable period. This period must be compatible with
the frequency of reading. The alarm can also be reset on demand via the optical connection.
NB: Any modifications of the default values must be approved in advance by Diehl Metering.
Otherwise, Diehl Metering shall not be liable for any malfunctioning of the product.
2.4 D
IMENSIONS
3
I
NSTALLATION PRECAUTIONS
3.1 I
DENTIFICATION
Make sure that IZAR RC 868 i G4 is compatible with the meter on which it is mounted
(marked "Ti" or "Ha + Ti").
3.2 S
ECURING SYSTEM
Hooks
View from underneath
Lock screw +
sealing label
6 | IZAR RC 868 i G4
fig.3
IZAR RC 868 i G4 features 3 fastening
hooks (fig. 5) to mount the module on
the meters of the Diehl Metering
inductive modular range.
fig. 5
A screw tightens and loosens the
ring on the meter (fig.6). This
system makes the assembly more
secure while making it possible to
remove the ring without damaging
the hooks.
Put the sealing label (delivered
with the radio module) on the lock
fig. 6
screw.
fig. 7
fig.4
05/2015