Loading
◇ Load should be distributed on the lift table equably.
Lifting the Lift Table
◇ Screw and loose emergency stop switch.
◇ Push the UP button and power pack starts to work to lift the load.
◇ Loose the UP button and power pack stops working.
Lowering the Lift Table
◇ Push the DOWN button and the table will lower.
◇ Loose the DOWN button and the table will stop.
NOTE: The table is equipped with an aluminum guard to avoid accidental
danger.
◇ If aluminum guard strikes an object while the table lowers, stop operation
and check the lift table. After making sure no any abnormality, strike the
UP button slightly and then the electric system will function as before.
Emergency Stop
There are two methods of emergency stop as follows.
◇ Push down the emergency stop switch and the movement of table stops.
◇ Strike aluminum guard upward and the movement of table also stops.
Transportation
If necessary, the lift table can be transported with attached ringbolts.
Pay attention to the maximum capacity of lifting equipment to be used.
Keep the ringbolts with reasonableness.
Maintenance
Do routine check of fasteners, packing and oil leaking.
Do routine check of the function of the lift table.
Before service the lift table, make sure to turn off the AC power supply.
After service it is necessary to check the function of the lift table again.
ONLY a qualified personnel can do service work.
Do routine check of the micro-switches on the safety guard.
Do routine check of the hydraulic system by listening its noise, touch
motor's surface.
Caution: It is necessary to turn off the AC power supply before touch
motor's surface.
Pay attention to clear or even replace the oil filter after operating for a
long time.
Appropriate lubrication is necessary to make the lift table work easily and
have a prolonged service life.
Following table is recommended to service the lift table periodically.
10