Temperature Setting; Preset Temperature; Fan Speed - Mitsubishi Electric City Multi PVFY-P12 NAMU-E1 Manuel D'utilisation

Masquer les pouces Voir aussi pour City Multi PVFY-P12 NAMU-E1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3. Temperature Setting

Preset temperature

In COOL, HEAT, and AUTO (single set point) modes
In COOL, DRYING, HEATING and AUTO (single set point) modes
Pressing the
button increases the preset temperature.
TEMP.
Pressing the
button increases the preset temperature.
TEMP.
Pressing the
button decreases the preset temperature.
TEMP.
Pressing the
button decreases the preset temperature.
TEMP.
In AUTO (dual set point) and SETBACK modes
In AUTO (dual set point) and SETBACK modes
Cooling preset temperature
Set to
Room
AUTO
COOLHEATFAN
DRYING VENTI. SETBACK
Heating preset temperature
Current operation mode
Set to
Room
AUTO
COOLHEATFAN
DRYING VENTI. SETBACK
Set to
Room
AUTO
COOLHEATFAN
DRYING VENTI. SETBACK
Set to
Room
AUTO
COOLHEATFAN
DRYING VENTI. SETBACK
* During the preset temperature setting, the setting will automatically turn off if the
button is left untouched for a certain period of time.
TEMP.
Preset temperature range is as follows.
Operation mode
Preset temperature range
COOL/DRYING
67 - 87 (95)°F/19 - 30 (35)°C
HEAT
63 (40) - 83°F/17 (5) - 28°C
AUTO (single set point) 67 - 83°F/19 - 28°C
AUTO (dual set point)
[COOL] Preset temperature range for COOL mode.
[HEAT] Preset temperature range for HEAT mode. *1, *2
SETBACK
[COOL] Preset temperature range for COOL mode.
[HEAT] Preset temperature range for HEAT mode. *2
FAN
Unsettable
*1 The preset temperatures for cooling and heating for AUTO (dual set point) mode will be used for those for
COOL/DRYING and HEAT mode.
*2 The preset temperatures for cooling and heating can be set under the following conditions.
• The cooling preset temperature is greater than the heating preset temperature.
• The difference between the cooling and heating preset temperatures is equal or greater than the minimum
temperature difference that varies depending on the indoor unit model to be connected.

Fan speed

Pressing the
button will change the fan speed in the following order.
FAN
AUTO
8
* The settable fan speed varies depending on the indoor unit model to be connected.
Current preset temperature (cooling/heating) appears.
* The example shows the display in AUTO (dual set point) mode.
When the
or
TEMP.
TEMP.
(cooling/heating) display blinks.
While the preset temperature (cooling/heating) display blinks, pressing the
button increases the preset temperatures for both cooling and heating,
TEMP.
and pressing the
button decreases the preset temperatures for both
TEMP.
cooling and heating.
When the
button is pressed, only the cooling preset temperature display
MODE
blinks.
While the cooling preset temperature display blinks, pressing the
increases the cooling preset temperature, and pressing the
decreases the cooling preset temperature.
When the
button is pressed, only the heating preset temperature display
MODE
blinks.
While the heating preset temperature display blinks, pressing the
button increases the heating preset temperature, and pressing the
button decreases the heating preset temperature.
Pressing the
button completes the preset temperature setting.
MODE
– 7 –
– 7 –
button is pressed, the preset temperature
TEMP.
TEMP.
TEMP.
TEMP.
ON
ON
button
button
TEMP.
or

Publicité

Chapitres

Table des Matières
loading

Table des Matières