Wall Outlet; Roof Outlet - WANDERS Tali Mode D'emploi Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
Gastype
A (min.-max.)
Nat. gas
1,0 m
Nat. gas
1,0 - 2,5 m
all dimensions are exclusive the length of the wall outlet
B
Gastype
B (min. -
A1 (min. -
max.)
max.)
Nat. gas
1 - 2,5 m 1,0 - 10,0 m 1,0 - 10,0 m
(A1 + A2 : B) : 1
Proportion vertical: horizontal (or 45
always at least 2 : 1
all dimensions are exclusive the length of the roof outlet

Wall outlet

Always allow one metre vertical before passing through the outer wall.
The maximum length for a horizontal segment is 3 metres.
Determine the location of the appliance and the exterior wall duct.
Make an opening of Ø 160 mm for the wall duct.
Connect the wall duct vertically with a curve to the mouth of the appliance, push them fi rmly together and place the clip
binding. The blue rubber ring ensures suffi cient sealing of the outlet of the fl ue gas system.
If the appliance is placed more than 1 meter from the outside wall, place the fi rst meter on top the appliance, then the elbow
followed by the wall outlet. Finally make sure the construction is gastight.

Roof outlet

The roof outlet may pass through any point of the roof, with a bend to the ridge, if so desired. The roof outlet is supplied with
a universally adjustable plate for a sloped roof, or with an adhesive plate for a fl at roof.
Determine the location of the hearth and the roof outlet.
Make an opening of Ø 160 mm.
26
B
B (min. - max.)
Reducer
0 - 2,0 m
NO
0 - 3,0 m
NO
A1 + A2
Reducer
(min. - max.)
NO
up) is
o
Gastype
A (min. - max)
Nat. gas
1,0 - 2,5 m
Nat. gas
2,5 - 10,0 m
all dimensions are exclusive the length of the roof outlet
Reducer
Ø 60 mm
Ø 40 mm