Placing The Concentric Channel System; Instructions For Placing The Outflow; Placing Possibilities For The Pipe System - WANDERS Tali Mode D'emploi Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Placing the concentric channel system

The combination of the device and the WANDERS concentric channel system (Ø 100 mm - Ø 150 mm) is approved in
accordance with the European CE directive for appliances burning gaseous fuels. Therefore, only this system may be used in
combination with the device. The warranty on the device expires if it is (partly or completely) installed in combination with a
diff erent channel system. The WANDERS concentric channel system (Ø 100 mm - Ø 150 mm) can be used in new construction
as well as existing chimneys.
Instructions for placing the outfl ow
The outfl ow of the pipe system can be placed on top of the roof or against the side wall of the
house.
Outfl ow on top of the roof
When placing the outfl ow on top of the roof, make sure that there is a distance of at least 50 cm
between the outfl ow and the edges of the roof, with the exception of a possible existing ridge.
You must also take the place of the outfl ow into account in relation to the existing ventilation
openings, movable windows and combustion air supply provisions. Please consult the national
and local requirements.
Outfl ow into the wall
When placing the outfl ow into the side wall, make sure that there is distance of at least 50 cm
between the outfl ow and the corners of the building, eaves, gutters, balconies and etceteras. You
need not have this distance when the outfl ow runs to at least the front side of the overhanging
part.
You must also take into consideration the place of the outfl ow in relation to the
existing ventilation openings, movable windows and combustion air supply
provisions. Please consult the national and local requirements.

Placing possibilities for the pipe system

The total length of the pipe system must never be more than 10 metres excluding the passage through the wall and the
outfl ow. The maximum horizontal length is 3 metres. A 90° square angle counts as a length of 2 metres. A 45° turn counts as
a length of 1 metre.
For the combined fl ue tube and combustion air supply you must apply one of the following set-up possibilities of the WANDERS
concentric pipe systems: with wall duct, with roof duct, or with roof duct with bend.
Because of the high outer temperatures of the fl ue system ( around ± 150°C) it's not allowed to use flammable materials
near the flue system. Therefore it is advised to surround the flue system, on locations where it is not in direct view, with non-
flammable materials. Make sure this construction is sufficiently ventilated (per floor) by installing ventilation grids near the floor
and the ceiling.
It's not allowed to insulate the concentric fl ue system.
Use universal wall brackets Ø150 mm to attach the sleeving of the concentric channel system [Ø 100 mm - Ø 150 mm].
Select one of the connection possibilities. Then build up the fi rst metre of concentric pipe from the counterpart in the appliance.
If you can see the blue rubber ring in the pipe from above, you will know that the assembly is correct. Keep a distance of at
least 5 centimetres between the outer wall of the concentric pipe and the ceiling. Always start with 1 meter vertical.
Pay special attention to proper installing when, due to circumstances, a part of the double-walled pipe system must be built in.
GB
Min.
50 cm
25

Publicité