1. Installation
Remove the furnace components from their packaging and place the unit
on a suitable table. Please observe the instructions on the outer
packaging. Make sure the voltage indicated on the rating plate complies
with the local power supply. If this is not the case, the furnace must not
be connected.
Mounting the cooling tray
A
Remove both screws (1) for the cooling tray and the transport
protection of the infrared camera.
Place the cooling tray (2) on the frame plate (3). Make sure that the
B
cooling tray is correctly positioned on the frame plate.
Secure the cooling tray with the two screws (1).
C
Placing the firing plate
D
The firing plate (4) can now be placed on the firing plate holder (5).
Mounting the furnace head
E
The furnace head is best mounted with the rear panel of the furnace
pointing towards the user. Lift the furnace head with both hands as
shown in the picture and place it on the furnace head mounting.
Mount the furnace head as shown in the picture until it
F
audibly snaps into place. Make sure that the firing plate or the
insulation is not damaged by mounting the furnace head.
A
1
C
1
E
B
2
1
3
D
4
2
F
5