PREPARING YOUR DISTILLER AND RESERVOIR
CAUTION: To prevent personal injury or property damage, do not plug
dis tiller into wall outlet until all parts have been cleaned and properly
installed.

INITIAL CLEANING

Before using your distiller and reservoir for the first time, follow the
steps below.
Boiling Chamber
Do not immerse boiling chamber in water or other liquid for cleaning.
Using a sponge or cloth, clean the interior of the boiling chamber with hot soapy
water. Rinse thoroughly with fresh water. Be sure the gasket is properly and
securely placed over the top rim of the boiling chamber before using the distiller.
Reservoir
Clean the inside of the reservoir tank with either vinegar or a paste made
of baking soda and water to remove any traces of manufacturing oils. Rinse
thoroughly with fresh water.
It is recommended you steam clean your distiller and reservoir prior to using
it for the first time. Complete this step AFTER the unit is completely assembled
(see pages 7-14). This is a disinfecting procedure.
Steam Cleaning Instructions
1) Remove the post carbon filter.
2) Be certain that the FAN switch is in the OFF position, then turn ON
the switch for the POWER only. You should hear the water begin to
fill the boiling chamber.
3) When sufficient water fills the boiling chamber the heating element
will turn on automatically. After 15 minutes you should notice steam
beginning to appear in the sight gauge.
4) Continue steaming the unit for approximately 20 minutes.
CAUTION: External surfaces will be HOT during this process. DO NOT
TOUCH UNIT.
5) Turn OFF the POWER switch and allow the unit to cool completely.
6) When the unit has cooled completely, put the post carbon filter
back in place.
7) Check all components, then turn ON both the FAN and POWER
switches.