15. Technical Data

Power supply ...................................2 type AAA/Micro batteries
Measurement range ........................-40 °C to +250 °C
Resolution ........................................0.1 °C
Measuring Tolerances .....................-40 °C to -30,1 °C // +/- 3 °C
.........................................................-30 °C to -18,1 °C // +/- 2 °C
.........................................................-18 °C to 100 °C // +/- 1 °C
.........................................................100 °C to 200 °C // +/- 2°C
.........................................................200,1 °C to 250 °C // +/- 3 °C
Length of the penetration sensor .....98 mm
Software prerequisites .....................iOS as of 7.1
.........................................................Android as of 4.3
Number of measured data ...............14400
Radio transmission ..........................Bluetooth
Radio range ..................................... m ax. 30 m in the free field
Ambience conditions ....................... 0 °C to +40 °C, humidity 10%
Storage conditions ........................... -20 °C to +60 °C, humidity
Dimensions ......................................160 x 33 x 30 mm (L x W x H)
Weight .............................................59 g (without batteries)
4.0
®
(much lower in buildings)
to 60%, non-condensing
10% to 60%, non-condensing