7.6 Battery replacement

The internal lithium CR2477 - 3.0 V battery ensures over 8 years battery life.
The symbol
The replacement is made by simply removing the front cover without disassembly
of the indicator from the control shaft and keeping unchanged all the configuration
parameters.
To simply remove the battery from the battery compartment, we recommend the
use of a magnet.

8. Programming mode

Press the key
the setting of PASS parameter (see table on page 28), the system may require
you to enter a password.
Press the key
Press the key
automatically dropped after 30 seconds of inactivity.
8.1 Programming parameters with numeric values
Press the key
Press the key
aw.
Always mention the source when reproducing our drawings.
is shown on the display when the battery replacement is required.
for 3 seconds to enter the programming mode. Depending on
to scroll through the list of parameters.
to exit the programming mode. The programming mode is
to increase the flashing digit.
to decrease the flashing digit.
Direct drive electronic position indicators