Operating instructions and warnings
only for qualified personnel
Programming of a delay:
1. Set DIP1=DIP2=ON: led lights on indicating that the device is programming.
2. Give un impulse to IN1 input (if you desire to memorize delay_on) or to IN2 input (if you desire to
memorize delay_off): the counting of delay to be programmed starts, the led executes a winking every
second.
3. Wait for desired times, give another impulse to the same input: the led executes some fast winking,
delay memorization is ended.
4. bring DIP1 and 2 into desired position.
Zero setting of a delay:
1. Set DIP1=DIP2=ON: led lights on indicating the device is programming.
2. Do activate and maintain active input IN1 (in case you want to zero delay_on) or IN2 (if you want to
zero delay_off) until the led executes some fast blinking: delay set to zero.
3. Bring again DIP 1 and 2 into desired position.
8.3 Radio receiver
SSE12 feeder includes a 433,92MHz built-in radio receiver accepting both transmitters with HCS
coding (complete rolling code or just part fixed), and HT12E dip-switch coding. The receiver memory
capacity can contain up to 40 different transmitters.
It is possible to choose, according to one's needs, which key of the memorized transmitters will activate
the IN1 input and which one will activate the IN2 input. Procedures for the memorizing and deleting of
the remotes are explained as follows.
Remotes momorization:
1. Set DIP1=DIP2=ON: led lights on to indicate that the device is programming.
2. Push the on board S2 key: led switches out to indicate that the receiver is learning.
3. Before the led switches on press the remote key you want to match to IN1 input.
4. Before the led switches on again, press the remote key you want to match to IN2 input (if any other key
has to be matched to IN2, go directly to point 5).
5. repeat points 3 and 4 for some other remotes.
Remotes cancelling:
1. Set DIP1=DIP2=ON: led lights on to indicate that the device is programming.
2. Press the on board S2 key and maintain it pressed until the led winks fast for a while: remotes memory
cancellation done.
9 MAINTENANCE
WARNING Any installation, maintenance or repair operation on the whole system must be carried
out exclusively by qualified personnel. All these operations must be performed only after disconnecting
the power supply, and operating in strict compliance with the electrical standards and regulations in
force in the nation of installation.
12
10 PRODUCT DISPOSAL
In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this
electrical product must not be disposed of as unsorted municipal waste. Please dispose of this product by
returning it to your local municipal collection point for recycling.