7] MOUNTING INSTRUCTIONS

Make sure that there are no pieces missing in the mounting kit. Get the right tools
according to the installation type (Drill, screw drivers, metre tape,...) and follow the
mounting instructions of the reader.
1
Measure and mark the center lines
to determine the reader position. Drill
the fi xing screw holes (Diametre: 4MM
for the mounting plate and 6MM for the
reader). Drill the wiring access area.
8] LIMITED LIFETIME WARRANTY [EXTRACT]*
CDVI warrants this product to be free from defects in material and workmanship, when it has been installed
in accordance with the manufacturer's instructions and has not been modifi ed or tampered with. Only product
recognized by CDVI to be defective should be returned under these warranty terms if accompanied
by an RMA (Return Material Authorization Number) provided by CDVI. CDVI, at its option, shall repair
or replace the defective product at CDVI premises or at any CDVI approved service center. This warranty
does not cover any damage due to accident, misuse, abuse or negligence. This warranty is valid only
if the product is registered, within 1 month from delivery to the fi nal costumer. To obtain full details of this
warranty and to register the product to commence the "Limited Lifetime Warranty", complete the enclosed
registration card and return it, either by e-mail or post, to the relevant CDVI address or completion of the
on line registration at www.cdvigroup.com. Repair or replacement of the defective product is the exclusive
remedy. CDVI shall not be liable for any incidental or consequential damages arising from any defect in, or
malfunction of, its product. In no event the entire liability can not exceed the purchase price of the product.
The CDVI local country contact details can be found on line by visiting www.cdvigroup.com or on the back
cover of the installation manual.
DISCLAIMER OF WARRANTY: EXCEPT AS STATED ABOVE, CDVI MAKES NO WARRANTIES, EITHER
EXPRESS OR IMPLIED, AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITION OF ITS PRODUCTS,
THE TRANSPORTATION, THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
*Refer to Limited Lifetime Warranty conditions
Card Readers - Wiegand Output
®
2
DGLIMWLC
Insert the brass anchors in the mounting
holes, connect the cable to the terminal
block, then fasten the reader with
the DIAX
screws using the DIAX
®
spanner.
Make
varistor is connected on the lock (refer
to page 2 «Recommendations»).
3
DGLPMWLC
Insert the plastic anchors in the mounting
holes, connect the cable to the terminal
block, Then fasten the reader with the
wooden screws Leave an area to access
®
sure
that
the
the cable to make the wiring). Put the
covers on top of the reader. Make sure
that the varistor is connected on the lock
(refer to page 2 «Recommendations»).