Improper use of the appliance;
Exceptional and unforeseeable events;
Unrespect to domestic legislation on health, hygiene and safety at the workplace;
The employer is responsible for the periodic training of the operators about the correct use, safety rules and fire prevention.
2.
TECHNICAL DATA
HOODS
Supply voltage
Frequency
Max. power input
Max. current requirement
Max. supply Voltage variation
Max. Frequency variation
Max. Frequency variation
WARNING!
3.
INSTALLATION AND COMMISSIONING
WARNING!
Proceed according to the following instruction before connecting the appliance:
Remove the packaging and then the protective film taking care not to scratch the surface;
Do not push or pull the appliance to avoid its overturning;
Appliances must be moved using a fork lift trolley. Insert forks under the pallet and move the appliance taking care that the load is properly balanced;
Place the appliance in order to grant its stability. If necessary carry out masonry reinforcement work, take into consideration that the height between
the floor and the hood lower part is 1900/2000 mm and that the perimeter of the hood must protrude by at least 200 mm with respect to the area of
cooking appliances;
The hood can be installed using the plugs and the chains supplied. If the ceiling is made by hollow brick, resin plugs (not supplied) must be used.
WARNING!
Mark the ceiling or the wall for plugs' fitting and drill;
Fit the plugs and adjust chains' length;
Fix eyebolts directly to the hood through the holes which have been already prepared;
Connect eyebolts trough the chains and "S" hooks;
The hood must be connected to an efficient flue directly to the outside having an adequate size based on the hood extraction capacity;
Make sure the power supply of the appliance shown on the data plate is compatible with the grid voltage;
Check the power supply of the system is set up and able to take the current load, and meets the legal requirements and domestic standards;
The appliance must be earthed;
In case of direct connection to the electricity grid (without plug), it's necessary providing for a wall switch or a contactor, which grant the complete
disconnection according to overvoltage III rate and accordingly to installation rules;
V
Hz
W (7/7) (9/9)
A (7/7) (9/9)
continuous
Short period
The electric power system and the rooms where the appliance is placed have to respect
domestic legislation on safety, accident prevention and fire regulations. On the
contrary the Manufacturer won't assume liability for direct and indirect damages to
people or things.
Intervention on the electric power system must be solely performed by specialized
electricians.
Plugs and chains are supplied to support only the weight of the hood.
220-240
50-60
200/420
2/3,15
+/- 10%
+/-1%
+/- 2%
8