AQUALUX 106003 Manuel D'installation Et D'utilisation page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Size(mm)
Model
106003
106004
106005
Above data is subject to modification without notice.
2.2.2. Heat pump installation.
① The frame must be fixed by bolts (M10) to concrete foundation or brackets. The
concrete foundation must be solid; the bracket must be strong enough and anti-rust
treated;
② The heat pump needs a water pump (Supplied by the user). The recommended pump
specification-flux: refer to Technical Parameter, Max. lift ≥10m
③ When the heat pump is running, there will be condensation water discharged from the
bottom, please pay attention to it. Please insert the drainage tube(accessory) into the
hole and clip it well, then connect a pipe to drain off the condensation water.
2.2.3. Wiring & protecting devices and cable specification
① Connect to appropriate power supply, the voltage should comply with the rated voltage
of the products.
② Well earth the heat pump.
③ Wiring must be connected by a professional technician according to the circuit
diagram.
④ Set breaker or fuse according to the local code (leakage operating current ≤ 30mA).
⑤ The layout of power cable and signal cable should be orderly and not affecting each
other.
E
B
Name
A
B
324 590 308 349
404 590 388 429
404 720 388 429 1084
For installers and professionals
C
A
D
C
D
E
954
340
954
390
620
- 27 -
F
G
H
74
648
74
648
74
948

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

106004106005

Table des Matières