2.2.2. Heat pump installation.
① The frame must be fixed by bolts (M10) to concrete foundation or brackets. The
concrete foundation must be solid; the bracket must be strong enough and anti-rust
treated;
② The heat pump needs a water pump (Supplied by the user). The recommended pump
specification-flux: refer to Technical Parameter, Max. lift ≥10m
③ When the heat pump is running, there will be condensation water discharged from the
bottom, please pay attention to it. Please insert the drainage tube(accessory) into the
hole and clip it well, then connect a pipe to drain off the condensation water.
2.2.3. Wiring & protecting devices and cable specification
① Connect to appropriate power supply, the voltage should comply with the rated voltage
of the products.
② Well earth the heat pump.
③ Wiring must be connected by a professional technician according to the circuit
diagram.
④ Set breaker or fuse according to the local code (leakage operating current ≤ 30mA).
⑤ The layout of power cable and signal cable should be orderly and not affecting each
other.