MENU STRUCTURE
PROGRAMMING THE PARAMETERS
DISPLAYING THE PROGRAMMED PARAMETERS
Rev 1.0
All manuals and user guides at all-guides.com
During normal operation of the pump it is possible to display the programmed
parameters by pressing the SET button.
The dosing stops and the pump displays subsequently:
-nA and the programmed number of dosings
-tA and the programmed total minutes of daily dosing
-FL and the programmed percentuage of the flow rate.
Remember that FS means Full Speed = 100% = maximum flow rate
Cod. 00.008.565
Push OK/SBY and then the
SET button to enter the
programming menu.
Navigate within the menu by
pressing SET and enter the
sub-menu to modify the
parameters by pressing
OK / SBY.
Once you enter the menu, change the
parameters
nA,
tA,
OK/SBY button and then select the
desidered value by SET button and
confirm it by pressing OK/SBY.
Exit the programming confirming the
value of the percentuage flow rate (FL)
by pressing OK/SBY.
The programmable Values are:
nA = 1-24; number of daily dosings (1
dosing every hour)
tA = 1-99 minutes; total daily dosing
time
FL = 10% - FS (Full Speed = 100%),
percentuage of the maximum flow of
the pump.
FL
pressing
7