The compressor may only be used in suit-
•
able rooms (with good ventilation and an
ambient temperature from +5 °C to 40 °C).
There must be no dust, acids, vapors, ex-
plosive gases or inflammable gases in the
room.
The compressor is designed to be used
•
in dry rooms. It is prohibited to use the
compressor in areas where work is con-
ducted with sprayed water.
8. Attachment and operation
m Important!
You must fully assemble the appliance
before using it for the first time!
You will require the following tools for as-
sembly and installation: 2 x open-ended
wrench size 14 mm (not included)
8.1 Fitting the wheels (fig. 6,7)
Screw on each wheel (3) one washer (C)
•
and one nut (B) on to the threads of the
wheels.
Then mount the wheels (3) on the wheel
•
holders, at the bottom of the pressure
vessel (2), by using a wrench to fix the
nut (B), washer (C) and flange nuts (D)
on the other side of the thread.
8.2 Fitting the supporting foot (fig. 5)
Mount the enclosed supporting foot
•
(4) with the two hex bolts (A), the two
washers (C) and two flange nuts (D), as
shown in Figure 5.
8.3 Fitting the holding (fig. 8)
Screw the holder 2 (E) in the threaded
•
holes on the right and left of the trans-
port handle (9), and secure the holder
with the nuts (8.1) against twisting.
8.4 Mains connection
The compressor is equipped with a
•
mains cable with shock-proof plug. This
can be connected to any 230V~ / 50 Hz
shock-proof socket which is protected by
a 16 A fuse.
20
GB
Before you use the machine, make sure
•
that the mains voltage is the same as
the operating voltage (see the rating
plate).
Long supply cables, extensions, cable
•
reels etc. cause a drop in voltage and
can impede motor start-up.
At low temperatures below +5 °C, slug-
•
gishness may make starting difficult or
impossible.
8.5 ON/OFF switch (fig. 2)
To switch on the compressor, press the
•
button (8) on position I.
To switch off the compressor, press the
•
button (8) on position 0.
8.6 Setting the pressure (fig. 2)
You can adjust the pressure on the pres-
•
sure gauge (6) using the pressure regu-
lator (7).
The set pressure can be taken from the
•
quick lock coupling (5).
8.7 Setting the pressure switch
The pressure switch is set at the factory.
•
Cut-in pressure approx. 8 bar. Cut-out
pressure approx. 10 bar.
9. Electrical connection
The electrical motor installed is con-
nected and ready for operation. The
connection complies with the applica-
ble VDE and DIN provisions.
The customer's mains connection as
well as the extension cable used must
also comply with these regulations.
Damaged electrical connection cable
The insulation on electrical connection ca-
bles is often damaged.
This may have the following causes:
Passage points, where connection ca-
•
bles are passed through windows or
doors.
Kinks where the connection cable has
•
been improperly fastened or routed.
Places where the connection cables
•
have been cut due to being driven over.
Insulation damage due to being ripped
•
out of the wall outlet.