SMART CHARGE IUoU Chargers
Front view 466095 (see figure 2)
The units can charge up to two supply batteries
No.
Description
1
Half power mode button
2
Connection for remote control
3
Control lamp
4
Switch field for the selection of the charging voltage
and time limitation (figure 8)
5
"+" (plus) terminal for the supply battery (1A Charge)
6
"+" (plus) terminal for the supply battery
7
"+" (plus) terminal for the supply battery
8
"-" (minus) terminal for the supply battery
5
Settings
5.1
Charging voltage and time
A switch field can select the charging voltage and the period for the main
charging phase.
Warning!
Make sure that switch 1 and 2 or switch 3 and 4 are never switched
on simultaneously while operating the charger. Please follow the
table below to ensure correct operation of the charger
5.1.1
Settings for the charging voltage
Refer to figure 8:
Voltage
Switch 1
Switch 2
Application range
13.8 V
OFF
OFF
Starter batteries, or using as a
12V power supply
14.4 V
ON
OFF
Lead acid and gel batteries
14.8 V
OFF
ON
AGM batteries
5.1.2
Settings for the limitation of the period of the main charging
phase
Refer to figure 8:
13
All manuals and user guides at all-guides.com
Time limitation of
No timer function
5.2
If you push the button "Half Power Mode", the output power will reduce to half
the chargers amp rating and a green "Half ON" LED will light. The Half Power
LED is located on the bottom left corner of the front panel.
6
For the mounting of battery charger on wall or flat places, please refer to figures
10 & 11 regarding size of housing and location of mounting holes for your
installation.
7
Note
Only use cables with the prescribed wire cross sections fro the connection of the
IU0U automatic charger to the battery.
SMART CHARGE IUoU Chargers
the main
Switch 3
Switch 4
charging
4 hrs.
OFF
ON
8 hrs
ON
OFF
OFF
OFF
Half power mode
Mounting of Battery Charger
Making Connections
Place the charger in a dry, cool, clean, and ventilated space.
o
Set the power switch to "0" (off) and pull out the main plug before
o
connection or disconnecting the direct current connection.
Connect the "-"(minus) battery pole with a connecting cable to
o
the"-"(minus) terminal at the IU0U automatic charger (see figure 1 & 2).
Connect the "+"(plus) battery pole with the connecting cable to the
o
"+"(plus) terminal at the IU0U automatic charger (see figure 1 & 2).
Lay all the cables from the batteries to the IU0U automatic charger (refer
o
to figure 6)
Fasten the cables ends with provided terminals (refer to figure 5).
o
For connection of starter batteries, please connect the terminal as our
o
drawing (see figure figure 7).
Ensure correct polarity of the battery and the battery charger, otherwise
o
the internal flat-pin terminal will trigger with the wrong polarity.
Application range phase
Lead acid or Starter batteries
AGM batteries or Gel batteries
Using as a 12V power supply
14