Télécharger Imprimer la page

OPTIKA MICROSCOPES SZM Serie Manuel D'instructions

Masquer les pouces Voir aussi pour SZM Serie:

Publicité

Liens rapides

All manuals and user guides at all-guides.com
M
I
C
R
O
S
C
O
P
E
S
I
T
A
L
Y
Ver. 2.0.1
SZM
OPERATION MANUAL
MANUEL D'INSTRUCTIONS
GUIDA UTENTE
GUIA DEL USUARIO
OPTIKA MICROSCOPES - ITALY
www.optikamicroscopes.com - info@optikamicroscopes.com

Publicité

loading

Sommaire des Matières pour OPTIKA MICROSCOPES SZM Serie

  • Page 1 All manuals and user guides at all-guides.com Ver. 2.0.1 OPERATION MANUAL MANUEL D’INSTRUCTIONS GUIDA UTENTE GUIA DEL USUARIO OPTIKA MICROSCOPES - ITALY www.optikamicroscopes.com - info@optikamicroscopes.com...
  • Page 2 All manuals and user guides at all-guides.com INDEX 1. DESCRIPTION page 3 2. INTRODUCTION page 4 3. UNPACKING AND ASSEMBLY page 4 4. USING THE MICROSCOPE page 5 Illumination system Adjust interpupillary distance Focus and regulation of the focusing tension Dioptric compensation Magnifi...
  • Page 3 All manuals and user guides at all-guides.com 1.0 DESCRIPTION TESTATA BINOCULARE OCULARI MANOPOLA PER INGRANDIRE ZOOM REGOLAZIONE DIOTTRICA ILLUMINATORE INCIDENTE SEDE DEGLI OBIETTIVI MANOPOLA MESSA A FUOCO PIANO DI OSSERVAZIONE CON DISCO INTERCAMBIABILE STATIVO REGOLAZIONE DELLA INTENSITÁ LUMINOSA BASE SZM-2 TESTATA TRINOCULARE TUBO PER APPLICAZIONI...
  • Page 4 All manuals and user guides at all-guides.com 2.0 INTRODUCTION The OPTIKA zoom stereo microscopes SZM series are high performance Greenough microscopes with continuous zoom system 0.7:4.5. These instruments are made for examining any three dimensional object in industrial, biological and educational applications.
  • Page 5 All manuals and user guides at all-guides.com 4.0 USING THE MICROSCOPE Illumination system The SZM-1 and SZM-2 come with an integrated illumination system with incident and transmitted light. For the microscopes without integrated illumination systems it is possible to use an external cold light source.
  • Page 6 All manuals and user guides at all-guides.com 4.0 USING THE MICROSCOPE Video capturing (optional) Two kinds of observation heads, binocular or trinocular, are available for the SZM series. They can all be connected to cameras via an adaptor, for digital and analogical photo and video capturing. Before taking a picture or fi...
  • Page 7 All manuals and user guides at all-guides.com 5.0 MAINTENANCE Changing the lamp bulb Before changing the bulb, make sure that the power switch is off and the power cord has been disconnected from the main supply. For incident light: unscrew the lamp collector piece and pull it out, remove the old light bulb from the socket, and carefully plug the new bulb in.
  • Page 8 White/black object-plate, type 2 dia. 95 mm ST-014 Glass stage, type 2, dia. 95 mm ST-038 Halogen bulb, 12V/15W ST-037 Halogen bulb, 12V/15W, with dichroic mirror ST-033 Dust cover type 13 Please contact Optika Microscopes for more information and a complete list of accessories. Page 8...
  • Page 9 Manual, but bring it back to the Distributor you bought it from, or to other M.A.D. or Optika Microscopes distributors. The Distributor shall collect the apparatus free of charge.
  • Page 10 All manuals and user guides at all-guides.com INDEX 1. DESCRIPTION page 11 2. INTRODUCTION page 12 3. DÉBALLAGE ET MONTAGE page 13 4. UTILISATION DU MICROSCOPE page 13 Système d’illumination Distance nterpupillaire Mise au point et réglage de la tension de la mise au point Compensation dioptrique Grossissement et distance de travail Acquisition photo/vidéo (facultative)
  • Page 11 All manuals and user guides at all-guides.com 1.0 DESCRIPTION TÊTE STÉRÉO OCULAIRE RÉGLAGE GROSSISSE-MENT ZOOM COMPENSATION DIOPTRIQUE ECLAIRAGE INCIDENT OBJECTIFS BOUTON DE COMMANDE MISE AU POINT PLATE-FORME D’OBSERVATION STATIF RÉGLAGE DE L’INTENSITÉ LUMINEUSE BASE SZM-2 TÊTE TRINOCULAIRE (POUR SZM-2/4) TUBE POUR APPLICATIONS PHOTO/VIDÉO SZM-4...
  • Page 12 All manuals and user guides at all-guides.com 2.0 INTRODUCTION Les stéréomicroscopes OPTIKA de la série SZM sont composés de microscopes Greenough, in- struments d’excellentes prestations, dôtés d’objectif zoom de grossissement continu 0.7x... 4.5x. Ces instruments sont désignés pour examiner tout objet en trois dimensions dans les applications industrielles, biologiques et didactiques.
  • Page 13 All manuals and user guides at all-guides.com 4.0 UTILISATION DU MICROSCOPE Système d’illumination Le SZM-1 et SZM-2 sont dôtés d’un système d’illumination intégré avec lumière incidente et tran- smise. Pour les microscopes sans système d’illumination intégré il est possible d’utiliser une source de lumière froide externe.
  • Page 14 All manuals and user guides at all-guides.com 4.0 UTILISATION DU MICROSCOPE Acquisition photo/vidéo (facultative) La série SZM est disponible en têtes d’observation binoculaire et trinoculaire. Il est possible de les connecter à une caméra ou à un appareil photo en utilisant un adaptateur pour la câpture d’image vidéo et pour l’acquisition de photographies numériques et analogiques .
  • Page 15 All manuals and user guides at all-guides.com 5.0 MAINTENANCE Changing the lamp bulb Avant de procéder à la substitution de la lampe, s’assurer que l’intérrupteur principal n’est pas en fonctionnement et que le câble d’alimentation n’est pas relié à la source d’alimentation électrique.
  • Page 16 All manuals and user guides at all-guides.com 7.0 ACCESSOIRES FACULTATIFS Liste des accessoires disponibles ST-081 Oculaires (couple) WF10x/20mm ST-082 Oculaires (couple) WF15x/15mm ST-083 Oculaires (couple) WF20x/10mm ST-084 Oculaire micrométrique WF10x/20mm ST-085 Lentille additionnelle 0,5x ST-091 Lentille additionnelle 0,75x ST-086 Lentille additionnelle 1,5x ST-087 Lentille additionnelle 2x ST-088...
  • Page 17 All manuals and user guides at all-guides.com 8.0 RÉCYCLAGE ET RÉCUPÉRATION INous vous prions d’utiliser l’emballage original lorsqu’il sera nécéssaire de réexpédier le microsco- pe à la Maison Optika pour l’entretien. Ce symbole sur l’appareil: Ce symbole signifi e que l’appareil peut être une source précieuse de produits de base et qu’il ne doit pas être jeté...
  • Page 18 All manuals and user guides at all-guides.com INDICE - DESCRIZIONE pag. 19 - INTRODUZIONE pag. 20 - DISIMBALLAGGIO E MONTAGGIO DEL MICROSCOPIO pag. 20 - ALLINEAMENTO E UTILIZZO DEL MICROSCOPIO pag. 21 - MANUTENZIONE DEL MICROSCOPIO pag. 22 - SISTEMA ELETTRICO pag.
  • Page 19 All manuals and user guides at all-guides.com 1.0 DESCRIZIONE TESTATA BINOCULARE OCULARI MANOPOLA DI REGOLAZIONE DELLO ZOOM REGOLAZIONE DIOTTRICA ILLUMINATORE INCIDENTE SEDE DEGLI OBIETTIVI MANOPOLA DI COMANDO DELLA MESSA A FUOCO CON CONTROLLO TENSIONE PIANO PORTA-PREPARATI STATIVO REGOLATORE DELLA LUMINOSITÀ BASE SZM-2 TESTATA TRINOCULARE...
  • Page 20 All manuals and user guides at all-guides.com 2.0 INTRODUZIONE Gli stereomicroscopi OPTIKA della serie SZM sono composti da stereomicroscopi Greenough dalle eccellenti prestazioni dotati di obiettivo a zoom ad ingrandimento continuo da 0,7 a 4,5. L’ingran- dimento totale varia da 1,75x a 180x in funzione degli oculari e degli obiettivi addizionali utilizzati. I microscopi SZM sono particolarmente indicati per lo studio in tre dimensioni di oggetti di grandi dimensioni per applicazioni di tipo industriale, per la ricerca biologica e per la didattica.
  • Page 21 All manuals and user guides at all-guides.com 4.0 ALLINEAMENTO E UTILIZZO DEL MICROSCOPIO Distanza Interpupillare Muovere i due tubi porta-oculari fi no ad ottenere la visione di un unico campo luminoso circolare. Se si vedono due cerchi, allora la distanza interpupillare è troppo grande. Se invece appaiono due cerchi sovrapposti, signifi...
  • Page 22 All manuals and user guides at all-guides.com 4.0 ALLINEAMENTO E UTILIZZO DEL MICROSCOPIO Tubo trinoculare per SZM Il tubo trinoculare è identico a quello binoculare per quanto riguarda la regolazione della distanza interpupillare e il blocco dell’oculare. Togliendo il dispositivo di scorrimento posto sulla parte posteriore del tubo trinoculare, tutta la luce proveniente dall’oculare destro verrà...
  • Page 23 All manuals and user guides at all-guides.com 5.0 MANUTENZIONE Nota: l’etanolo e l’etere sono liquidi altamente infi ammabili. Da non utilizzare vicino a fonti di calore, scintilla o attrezzature elettriche. Utilizzare in ambiente ben aerato. • Non strofi nare la superfi cie di nessuna componente ottica con le mani. Le impronte digitali possono danneggiare le ottiche.
  • Page 24 All manuals and user guides at all-guides.com 7.0 ACCESSORI OPZIONALI Adattatore fotografi co Questo accessorio montato sulla testata trinoculare permette l’utilizzo di una macchina foto- grafi ca di qualsiasi marca sul microscopio per l’acquisizione di foto. L’anello T2 relativo al tipo di macchina fotografi...
  • Page 25 Direttiva in vigore. Attenzione: la Legge prevede sanzioni per chi smaltisce abusivamente apparecchiature riportanti il simbolo sopraindicato. M.A.D. Apparecchiature Scientifi - che – Optika Microscopes declina ogni responsabilità verso chi smaltisce o modifi ca l’apparecchio in modo difforme da quanto qui precisato.
  • Page 26 All manuals and user guides at all-guides.com INDICE - DESCRIPCIÓN pag 27 - INSTALACIÓN Y PREPARACIÓN AL USO pag 28 - ALINEACIÓN Y USO DEL MICROSCOPIO pag 29 - MANTENIMIENTO DEL MICROSCOPIO pag 30 - ELECTRICS pag 31 - OTROS ACCESORIOS pag 31 - MEDIDAS ECOLÓGICAS pag 32...
  • Page 27 All manuals and user guides at all-guides.com 1.0 DESCRIPCIÓN CABEZAL OCULARE BINOCULAR MANDO DEL ZOOM DE LOS AUMENTOS REGULACIÓN DIÓPTRICA ILUMINADOR INCIDENTE SEDE DE LOS OBJETIVOS MANDO DEL ENFOQUE PLATAFORMA DE OBSERVACIÓN DE MUESTRAS CON DISCO INTERCAMBIABLE ESTATIVO REGULACIÓN DE LA INTENSIDAD LUMINOSA BASE...
  • Page 28 All manuals and user guides at all-guides.com 2.0 INSTALACIÓN Y PREPARACIÓN AL USO La serie de estéreomicroscopios SZM está expresamente dedicada a los laboratorios y a la indu- stria. Sus características funcionales, la calidad óptica y mecánica ha conseguido convertir esta serie en una referencia para el mercado por su relación calidad/precio.
  • Page 29 All manuals and user guides at all-guides.com 3.0 ALINEACIÓN Y USO DEL MICROSCOPIO Distancia interpupilar Mirar a través de los oculares y mover los dos tubos porta oculares hasta obtener la visión de un único campo circular. Enfoque del estereomicroscopio Colocar una muestra para visionar en el plano de observaciones.
  • Page 30 All manuals and user guides at all-guides.com 5.0 MANTENIMIENTO Ambiente de trabajo Se aconseja utilizar este microscopio en un ambiente limpio y seco; también se deben evitar los im- pactos. La temperatura de trabajo recomendada es de 0-40°C y la humedad relativa máxima es de 85 % (en ausencia de condensación).
  • Page 31 All manuals and user guides at all-guides.com 6.0 ELECTRICS Universal Power: 230 V, 50/60 Hz Lamp (transmitted light): 12V/15W Halogen bulb Lamp (incident light): 12V/15W Halogen bulb with dichroic mirror 7.0 OTROS ACCESORIOS ST-081 Pareja de oculares WF10x ST-082 Pareja de oculares WF15x ST-083 Pareja de oculares WF20x ST-084...
  • Page 32 Estas materias primas, si se dispersan en el ambiente, pueden provocar daños al medio ambiente y a la salud de los ciudadanos. El fabricante del instrumento, M.A.D. Apparecchiature Scientifi che – Optika Microscopes, así como la Administración, se harán cargo de defender el medio ambiente, recuperando, reutilizando y reci- clando las materias primas del instrumento.
  • Page 33 All manuals and user guides at all-guides.com...
  • Page 34 All manuals and user guides at all-guides.com...
  • Page 35 All manuals and user guides at all-guides.com...
  • Page 36 Curieweg 14 - 3208-KJ Spijkenisse - Netherlands Tel.: +31 (0) 181657028 Fax: +31 (0) 181657110 MAD Iberica C/ La Lluna, 11 - 08001- Barcelona - ESPAÑA Tel.: +34 93 3248682 Fax: +34 93 3248683 OPTIKA MICROSCOPES - ITALY www.optikamicroscopes.com - info@optikamicroscopes.com...

Ce manuel est également adapté pour:

Szm-2Szm-4