04. Cleaning and maintenance

Always be sure to disconnect the plug from the socket first before
carrying out any work or cleaning on the heating unit. Remove the
outer panel and use compressed air to clean. Do not use water.
If water has been used to clean the dismantled outer panel, do not
replace the outer panel until you have convinced yourself that it is
absolutely dry.
06. Faults and Troubleshooting (TDE 25)
Faults:
Unit switched on – fan fails to turn.
Fan turns – no heated air discharged.
06. a) Faults and Troubleshooting (TDE 65 / TDE 95)
Faults:
Fan turns slowly.
Fan is running normally, but hardly any
heat generated.
Fan is running normally, heating per-
formance low.
Fan isn't running.
Electric heating unit fails to respond
to switch.
Footnote 1: If you are unable to correct the fault, please consult an electrician.
Footnote 2: Please contact the dealership where the article was purchased.
Footnote 3: If only one fuse is defect, performance will drop to 50% of the set value.
B - 2

05. Technical data

Typ
Heating
performance
Air flow rate
Voltage
Operating voltage 13.4 A
Clinxon thermostat 63 °C / 25 A
Fuse connection
Room thermostat
Discharge nozzles 155 mm
Dimensions
Weight
Possible Cause:
No power, cable, on/off switch or
thermostat defect.
Heating coil defect.
Possible Cause:
Fuse defect (see footnote 3).
The blue wire of the 3P + N + earth
plug is on N instead of a phase.
Switch is set to Pos. 2 = 50% and
fuse faulty.
Faulty fuse (see footnote 3).
The blue wire of the 3P + N + earth
plug is on N instead of a phase.
Heating element defect.
No power.
Fan motor defect.
No power.
Switch defect.
Operating Instructions – Electric heating unit
TDE 25
TDE 65
3 kW
6 - 9 - 12 kW
2586 kcal/h
5160/7740/10300 kcal/h 7740/11610/15400 kcal/h
250 m³/h
600 m³/h
230V / 50 Hz 400V / 50 Hz
18 A
82 °C / 25 A
16 A
32 A
accessory
300 mm
315x260x355 605x365x465
LxWxHmm
11 kg
25 kg
Troubleshooting:
Check power connection, cable, on/off switch,
thermosat, renew if necessary.
Open control box, check heating coil connections,
renew if necessary.
Troubleshooting:
Renew fuse (see footnote 1).
Check plug and attach the blue wire to L1, L2, or L3.
(see footnote 1).
Check fuses. 50% of 50% = 25% (see footnote 3).
Renew fuse (see footnote 1).
Check plug and attach the blue wire to L1, L2, or L3.
(see footnote 1).
Technical defect (see footnote 2).
Check if three-phase plug is properly plugged in,
check fuses at distributor, cable, feed cables (see
footnote 1).
Technical defect (see footnote 2).
Check to see if three-phase pulg is properly plugged
in, check fuses at distributor, check cable/feed
cable (see footnote 1).
Technical defect (see footnote 2).
TDE 95
9 - 13.5 - 18 kW
1520 m³/h
400V / 50 Hz
27.2 A
63 °C / 25 A
32 A
accessory
300 mm
480x405x585
30 kg