CH5
CH6
CH7
CH8
CH9
CH10
CH11
5. DMX 512 Connection
The DMX 512 is widely used in intelligent lightings and with a maximum of 512 channels.
1.
If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable.
2.
At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W
resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-
output of the last unit.
3.
Connect the unit together in a 'daisy chain' by XLR plug from the output of the unit to the input
of the next unit. The cable cannot be branched or split to a 'Y' cable. DMX512 is a very high-
speed signal. Inadequate or damaged cables, solder joints or corroded connectors can easily
distort the signal and shut down the system.
4.
Each lighting unit needs to have an address set to receive the data sent by the controller. The
address number is between 0-511 (usually 0 & 1 are equal to 1).
0-255
0-255
0-255
0-255
0-255
0-255
0-7
8-255
ALL RED (0-100%)
ALL GREEN (0-100%)
ALL BLUE (0-100%)
ALL WHITE (0-100%)
ALL AMBER (0-100%)
ALL UV(0-100%)
CH5-CH1
CCT (CH3<15)