Télécharger Imprimer la page

Publicité

Liens rapides

REM-45-KFA-B / REM-80T-KFA-B / REM-140T-KFA-B / REM-175T-KFA-B / REM-215T-KFA-B
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. For Example:
150812779. Have your Serial Number ready before calling customer service at 800-641-6996.
DANGER
sure to comply with the instructions and warnings provided with this heater. Failure to
comply can result in fire or explosion that can cause property loss, bodily injury, or loss
of life. Only persons who can follow and understand these instructions should operate or
service this heater. If you need heater info; such as an operating manual, labels, etcetera,
contact Pinnacle Climate Technologies at 800-641-6996.
DANGER
INDOOR USE ONLY IN WELL-VENTILATED AREAS. INDOOR USE PERMITTED ONLY
FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR
STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is an unvented
portable heater that uses air (Oxygen) from within the area in which it is used. Failure
to provide adequate combustion and ventilation air will result in asphyxiation, carbon
monoxide poisoning, bodily injury or death. Refer to "Ventilation" on Page 6.
FACTORY ID: 500
MODEL NUMBERS:
GENERAL HAZARD WARNING: READ AND UNDERSTAND
ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN
ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION.
THIS HEATER IS SUITABLE FOR OUTDOOR USE, AND
Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com
KEROSENE FORCED AIR HEATER
User's Manual &
Operating Instructions
Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
© 2021 Pinnacle Climate Technologies, Inc.
RBKO-403

Publicité

loading

Sommaire des Matières pour Pinnacle Climate Technologies REMINGTON REM-45-KFA-B

  • Page 1 Only persons who can follow and understand these instructions should operate or service this heater. If you need heater info; such as an operating manual, labels, etcetera, contact Pinnacle Climate Technologies at 800-641-6996. NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN DANGER ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION.
  • Page 2 REGULATION OF AUTHORITIES HAVING JURISDICTION AND CSA STANDARD B139. Look for this icon throughout the manual for helpful tips on how to assemble, use and clean your KFA Heater. © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 3 100,000 Btu/Hr (29 kW) TOUCH. KEEP CHILDREN, ANIMALS, heater rating. Refer to “Ventilation” on page 6 for CLOTHING AND COMBUSTIBLES AWAY further instructions. FROM HEATER. © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 4 Axle Wheel Support Frame Axle Supports - Remove the heater and all packaging materials Note: Save the box and packaging materials from the shipping carton for future storage. © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 5 7. Check all parts to ensure they are secure before Spacer Figure 1 operating the heater. 2. Attach the axle supports by inserting them into the button spring clips at the front of the bottom support frame. © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 6 - NEVER use kerosene that has been stored from one season to the next. Kerosene deteriorates over time. OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER. © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 7 “LO”. - When the temperature is more that 99 ºF the display says “HI”. - Between 0 °F and 99 °F the display shows actual temperature. © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 8 The wire should be lying on the bottom shell inside the heater with the plastic end placed Lint Filter End Filter under the motor support/motor and away from Figure 3 fan blade. © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 9 It may be necessary to soak the nozzle in K-1 kerosene to loosen any dirt particles. Nozzle Nozzle Face Photocell Wire Burner Head Figure 7 Figure 5 © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 10 OR WHILE CONNECTED TO A POWER SOURCE WIRING DIAGRAMS 45-KFA 80T - 215T-KFA 80T-KFA 140T-KFA / 175T-KFA / 190T-KFA (80T-KFA) (140T-KFA) (175T-KFA / 190T-KFA / 215T-KFA) Models 140T/175T/190T/215T-KFA have a digital display. © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 11 3. Check / replace the fuse. 4. Improper electrical connection 4. Inspect all electrical connections between temperature limit sensor (see wiring diagrams on page 10). and circuit board. © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 12 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE EXPLODED VIEW 33** 39** 34** 36** 35** 41** 37** * 45-KFA - 80T-KFA Only ** 140T-KFA - 215T-KFA Only 41** © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 13 70-056-0210 Cord Wrap 70-032-0100 70-032-0100 70-032-0200 70-032-0200 70-032-0200 Motor Supporter 70-020-0600 70-020-0600 70-020-0610 70-020-0610 70-020-0610 Axle Frame – – 70-041-0735 70-041-0735 70-041-0735 TIP: To order parts call 800-641-6996. © 2021 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 14 LIMITED WARRANTY Pinnacle Climate Technologies, Inc. warrants this heater to If Pinnacle Climate Technologies, Inc. finds the item to the original retail purchaser only, to be free from defects in be in normal operating condition, or not defective the item material and workmanship for a period of one (1) year from will be returned freight collect.
  • Page 15 à la propriété, des blessures ou même la mort. Seules les personnes pouvant suivre et comprendre ces instructions devraient utiliser ou entretenir cette chaufferette. Pour obtenir plus de renseignements (manuel d’utilisation, étiquettes, etc.), contacter Pinnacle Climate Technologies au 800-641-6996. NE PAS UTILISER DANS DES ZONES RÉSIDENTIELLES OU DANGER DANS DES ESPACES CLOS SANS VENTILATION ADÉQUATE.
  • Page 16 DES AUTORITÉS AYANT JURIDICTION ET LA NORME CSA B139. Rechercher cette icône dans le manuel pour des conseils utiles sur la façon d’assembler, d’utiliser et de nettoyer la chaufferette KFA. © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 17 TOUJOURS utiliser uniquement l’alimentation électrique ANIMAUX ET À L’ÉCART DES VÊTEMENTS (tension et fréquence) indiquée sur la plaque signalétique OU DE TOUT MATÉRIAU COMBUSTIBLE. de l’appareil. © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 18 - Retirer l’appareil et tout le matériel d’emballage Remarque : Conserver la boîte et les matériaux du carton. d’emballage pour y ranger ultérieurement la chaufferette. © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 19 Bague d’espacement Figure 1 2. Fixer les supports d’essieu en les insérant dans les attaches à ressort à l’avant du châssis de support inférieur. © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 20 à peinture ou d’autres 175T-KFA 215T-KFA composés d’huile dans cette chaufferette. CES 5.3 ft.² 6.5 ft.² COMBUSTIBLES VOLATILES PEUVENT 4924 cm² 6039 cm² PROVOQUER UN INCENDIE OU UNE EXPLOSION. © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 21 - « HI » (Élevée) lorsque la température ambiante est supérieure à 37 ºC. - Entre -18 °C et 37 °C l’afficheur indique la température réelle. © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 22 à l’intérieur de la chaufferette, son extrémité en plastique étant placée sous le moteur et le support du moteur, loin des ailettes du ventilateur. Filtre à charpie Filtre d’extrémité Figure 3 © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 23 K-1 propre pour détacher toute particule. Lentille de la cellule photoélectrique Buse Face de la buse Fil de la cellule photoélectrique Tête du brûleur Figure 7 Figure 5 © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 24 INTERRUPTEUR FUSIBLE LIMITEUR D’ALIMENTATION NOIR FICHE ÉLECTRIQUE NOIR 120 VCA JAUNE BLANC 60Hz REMARQUE : Les modèles VERT 140T/175T/190T/215T-KFA ont un affichage numérique. BLANC TERRE © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 25 4. Vérifier toutes les connexions carte de circuits imprimés. électriques en suivant les Schémas de câblage (page 10). © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 26 BRANCHÉE À UNE SOURCE DE COMBUSTIBLE. VUE ÉCLATÉE 33** 39** 34** 36** 35** 41** 37** * 45-KFA - 80T-KFA seulement ** 140T-KFA - 215T-KFA seulement 41** © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 27 70-032-0200 Support de moteur 70-020-0600 70-020-0600 70-020-0610 70-020-0610 70-020-0610 Supports d’essieu – – 70-041-0735 70-041-0735 70-041-0735 CONSEIL : Pour commander des pièces, composer le 800-641-6996. © 2021, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au kérosène...
  • Page 28 SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE DE COMBUSTIBLE. GARANTIE LIMITÉE Pinnacle Climate Technologies, Inc. garantit à l’acheteur au Si Pinnacle Climate Technologies, Inc. détermine que détail d’origine seulement que cet appareil sera exempt de l’article est dans un état d’utilisation normale, ou n’est pas défauts de matériau et de fabrication pendant une période...