In order to recalibrate sensors you will need to manipulate potentiometers. Do it
carefully as they arehighly sensitive electronical components.
Turn potentiometers with a flat head screwdriver clockwiseor counterclockwise,
whichever applies.
IR SENSORS REGULATION:
P2
(+)
turn counterclockwise.
(-)
turn clockwise.
Left
Sensor
Pag.9
HAND DRYER JET SMART
Right
Sensor
Electronical plate
with potentiometers
to calibrate hand
detection sensors
P1 (Right sensor):
(+)
turn clockwise.
(-)
turn counterclockwise.