Publicité

TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR
PRODUCT WITH THE POWER CONNECTED. DON'T JUST UNSCREW
THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM
THE RECEPTACLE.
TROUBLE
PROBABLE CAUSE
Switch is off position
Motor does
Blown fuse
not run.
Tripped breaker
Switch port clogged
Defective switch
Defective motor
Improper voltage
Motor runs
but no water
'P' trap between strainer
is delivered.
and pump
Improper voltage
Pump does
not deliver to
'P' trap between strainer
full capacity.
and pump
Defective switch
Pump does
Air in suction line
not shut off.
Missing check valve
Clogged check valve
in open position
Defective switch
Pump starts
Pump discharge too fast
and stop too
often.
on low head
Water pumped faster
than tub is filled
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where you've
purchased the pump, please contact us at 514 337-4415 , and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.
ACTION
Turn switch to on position
Replace
Reset
Remove and clean switch, port, adaptor
Replace
Replace
Check voltage
Remove
Check voltage
Remove
Replace
Check for proper pipe slope to pump inlet
Install valve
Clean debris
Replace
Install ball valve in discharge line to
reduce flow rate
It is normal
6