Télécharger Imprimer la page

Burcam 300514WH Instructions D'installation page 4

Pompe pour bassin de lavage

Publicité

Connect the 3 prong plug of the switch in a receptable. Insert the motor
STEP 6
3 prong plug into female receptable on exposed piggy-back of the
switch plug.
Test pump operation by filling laundry tub with water. Check all plumbing
STEP 7
connections for leaks and correct where necessary. The switch will activate
the pump's motor at about 1''- 4'' depht of water in tub, and shut off when
water will be drained out by the pump action. If a residue of water remain
in the laundry tub when the motor shuts off, you need to add a short pipe
section between the strainer and the union to lower the pump.
The laundry pump capacity maybe greater than the gravity inlet flow,
STEP 8
causing the pump to cycle ''on-off''. Upon this occurs, reduce the discharge
flow by installing a ball valve to adjust with the gravity flow at pump inlet, to
maintain a constant flow.
STEP 6
Connect switch
and pump to
receptacle
STEP 7
Test pump
operation
LAUNDRY TUB APPLICATION
STEP 2
Using the
supplied union,
install pump
under strainer
Pipe section
if required
STEP 5
Run the
discharge pipe
STEP 3
Screw the
union to
hold the pump
in place
Check
valve
1 1/4'' piping
STEP 4
Run the piping
and install
the check valve
4
1 1/2''
piping
Not
included
1 1/2''
piping
STEP 8
Adjust
discharge flow
if required

Publicité

loading