User manual
• 2.3 Advanced MENU : Beware and keep your settings in mind.
Keep pressed ENTER button for 3 seconds allows you to enter the hidden sub-menu to access advanced settings
- Maximum heating temperature: Default is 585 but here you can adjust from 530 to 600°C.
Advanced user should test what a different setting will render, just don't modify this setting if you're not sure of
what you are looking for. The display will show actual temperature on the Left and the setting temperature on
the Right.
-
Backlight : Allows you to tune the display's backlight from 1 to 10.
-
Sound Set : On/Off setting to enable SOUND MODE, don't forget when On.
-
Exit menu : Will ask to press enter to exit sub-menu to go back to the usual menu.
•
3. Important Notes :
-
To remove Seeds from the machine, Remove the power cord
from mains power, and allow unit to cool down. Empty the
storage bin through feed port by inverting the machine.
- Before storing the machine, empty the storage bin, clean it
and take a look into the output nozzle to verify if clean or to
remove anything in there. Keep the machine in dry cool place.
- Run the machine to generate Spark till out of Spark Seed, or
run Consumable Cleaning Up procedure (Safety channel,
channel 2) to completely clear remaining Spark Seed in the nozzle.
- Spark Seed would easily get damp in the open air and deliver
poor spark effect. Storing damp Spark Seed in the machine storage
bin will do harm to machine and cause clogging. Please empty the
storage bin after each use.
- Spark Seed should be stored in a cool, dry place, vacuum
packed in resealable foil bags, and protected from moisture, heat,
hot surface, open fire and other ignition sources.
- Store the unfinished Spark Seed in the Recycling Tube with the
Keep it sealed and away from moisture.
• 4. Troubleshooting
Errors
Over heat shutdown
Heating up failed
Over current protection for
motor
Thermocouple failed
Thermocouple tripped off
No remaining run-time
Internal temperature too high
Motor error
Power line frequency abnormal
Display
Possible Cause
The heating system temperature is higher
E0
than 700 ℃ over 30 seconds.
Heating system cannot reach pre-set
E1
target temperature after 10-min heat-up
E2
Consumable feeding motor failed
Short circuit or wrong connection of
E3
thermocouple
Open circuit or no connection of
E4
thermocouple
E5
No remaining run-time
The internal temperature is higher than
E6
E7
Stepper motor cannot be reset.
E8
Power input frequency is abnormal
V-1 Spark Machine
Funnel.
60°
13