Publicité

Liens rapides

Original instructions
Panther S 20/30 kW
GB
.... 11
FR
....13

Publicité

loading

Sommaire des Matières pour Frico Panther S 20 kW

  • Page 1 Original instructions Panther S 20/30 kW ..11 ..13...
  • Page 2 Regulation also does not apply to installations in vehicles, offshore or outdoors. Many of Frico's products can be used as both local space heaters (as defined in (EU) 2015/1188) and for technical heating purposes. It is up to the installer responsible for the installation to assess whether the Ecodesign Regulation is applicable or not.
  • Page 3 Panther S 20/30 Bracket / Console Wall / Mur Ceiling / Plafond 30° min 300 min 300 min 1000 Fig. 1b: Minimum distance wall 7 ,5° 15° Fig. 2 min 1800 Fig. 3 Fig. 1a: Minimum distance ceiling...
  • Page 4 Panther S 20/30 Controls / Régulation SIRe SIReFCY SIReFAY SIReRTX 70x33x23 mm SIReFCY/SIReFAY SIReUR SIReUR 114x70x50 mm SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 SIReCC610 10 m SIReRTX SIReCJ4/SIReCJ6 SIReCC615 15 m SIReCC640 40 m SIReCC403 SIReCC405 10 m SIReCC410 SIReCC415 SIReCC Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188 Régulation pour les installations non couvertes par la réglementation relative à...
  • Page 5 Panther S 20/30 Technical specifications / Caractéristiques techniques ∆t* Type Output Airflow Sound Motor Voltage Amperage HxWxD Weight steps level* [kW] [m³/h] [dB(A)] [°C] [mm] [kg] SE20S 0/10/20 1900/2600 42/60 31/23 400V3N~ 29,5 576x478x545 SE30S 0/10/20/30 1900/2600 42/60 47/34 400V3N~ 43,9 576x478x545 ) Conditions: Distance to the unit 3 metres.
  • Page 6 Panther S 20/30 Internal wiring diagram Panther S 20 SE20S °C 6,3A 6,3A L1 L2 L3 N 1 2 3 4 5 6 7 8 9 10 11 12 400V 3N~...
  • Page 7 Panther S 20/30 Internal wiring diagram Panther S 30 SE30S °C 6,3A 6,3A L1 L2 L3 N 1 2 3 4 5 6 7 8 9 10 11 12 400V 3N~...
  • Page 8 Panther S 20/30 SIReFC ALARM OUT (BMS) (potential free contact, max 3A, 230V) EXTERNAL ON/OFF, 5-30V AC/DC EXTERNAL RPM 0-10V DC IN EXTERNAL ALARM IN (potential free contact) EXTERNAL SETBACK TEMP. ON/OFF (potential free contact)
  • Page 9 Panther S 20/30 SIReFA BMS INDICATION OUT (potential free contact max 3A, 230V) ALARM OUT (BMS) (potential free contact, max 3A, 230V) EXTERNAL ON/OFF, 5-30V AC/DC EXTERNAL HEAT 0-10V DC IN EXTERNAL RPM 0-10V DC IN EXTERNAL ALARM IN (potential free contact) EXTERNAL SETBACK TEMP.
  • Page 10 Panther S 20/30 Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188 Régulation pour les installations non couvertes par la réglementation relative à l'écoconception (UE) 2015/1188 SIReUB1 SIReUB1 SIReRTX SE06-15S Unit 1 SIReB1/B2/B1EC (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m...
  • Page 11 Panther S 20/30 Consignes de montage et mode d'emploi Généralités préférence doté d’une lampe témoin. Lisez attentivement les présentes consignes S’agissant des raccordements externes il y a avant d'installer et d'utiliser l'appareil. 4 passe-fils à l’arrière qui doivent être munis Conservez ce manuel afin de pouvoir le d’un passage pour le branchement répondant consulter ultérieurement.
  • Page 12 Panther S 20/30 fumée ou une odeur résultant de la poussière autre, lorsqu'il n'est pas en service pendant ou saleté éventuellement accumulée à une période prolongée. l'intérieur de l'appareil peut se dégager. Ce phénomène est tout à fait normal et disparaît Emballage rapidement.
  • Page 13 Panther S 20/30 • Les enfants âgés de 3 à 8 ans sont autorisés à allumer et éteindre l'appareil, à condition qu'il soit placé et installé dans sa position de service habituelle et que les enfants soient rigoureusement surveillés et formés sur la façon d'utiliser l'appareil de façon sure et sur les dangers que cela implique.
  • Page 14 Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...

Ce manuel est également adapté pour:

Panther s 30 kw