ALIGNMENT AND ADJUSTMENTS
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Data Display Mode
Definition of Data Display Mode:
-
Display Mode 1 : Temperature data(Celsius)
-
Display Mode 2 : Average Touch Sensor data for 1 minute
-
Display Mode 3 : Average Temperature(Celsius) data for 1minute
How to Enter:
-
With Power On, press AdjustUp Key + AdjsutDown Key for 7 seconds until it sends out a
beeping sound .
-
If not pressed any keys for 5 minutes, it will be set back from Data Display Mode
-
If pressing AdjustUp Key in this mode, Display Mode will be increased.
-
If pressing AdjustDown Key in this mode, Display Mode will be decreased.
• Converting °C  °F
Celsius(°C)
Fahrenheit(°F)
System Check Mode
Definition of System Check Mode:
-
" t2 " will display.
-
System Check Mode(t2 mode) Progress Function Performed Start/Pause
Motor(CW) Relay On  Heater Relay On  Heater Relay Off, Motor(CW) Relay Off
How to Enter:
-
While in Power Off, pressing the Dry Level + Power keys simultaneously will put the dryer into
the System Check mode
Technical_information-03044B_EN.indd 4
All manuals and user guides at all-guides.com
WARNING
-30
-10
10
-22
14
50
4
30
50
70
86
122
158
F =9/5C + 32
2012-05-30