FIREPLACE FRAMING AND INSTALLATION
1.
After gas and electrical hookup is completed, lower and
secure the burner assembly (leave two supports in bottom of
fireplace for future use) with the two screws removed in Step
9 on page 13.
2. Install the glass wind panel (two used on see-through fire-
places). See Figure 24.
3.
Reinstall the pivot bolts and washers removed in step 8 on
page 13 and reinstall the control door.
4.
Unscrew the igniter button and install the AA battery provided
in the instruction envelope prior to closing the control door. See
Figure 25.
Framing and Finishing
The fireplace can be installed with panels around the opening as
a clean face installation. See Figure 26. The top and sides must
use non-combustible panels (provided) where shown going over
the face of the fireplace. Outside of this area, any weatherproof
wall board may be used.
35305-3-0317
Figure 24
Figure 25
Figure 26
FINISHING
The fireplace can also be installed with panels flush with the
face of the fireplace. See Figure 27. In this application, the two
top non-combustible panels (provided) are required above the
fireplace. Outside of this area including the sides outside of the
fireplace's metal may be any weatherproof wall board.
To complete installation place non-combustible panels above
fireplace opening. Center panels on fireplace and secure with
screws into frame. With the non-combustible panels in posi-
tion, predrill 1/8-in. diameter holes through the non-combustible
panels and top mounting standoffs before running the screws into
the top mounting standoff. Place non-combustible panels on the
sides of the fireplace opening. Secure with screws into the frame
and pre-drill 1/8-in. diameter holes into the fireplace face. Finish
remaining wall with weather-proof wall board.
NOTE: If installing the wall board in the flush face configuration,
trim the two top panels to 16-1/2 in. x 26-3/4 in. The
smaller non-combustible panels will not be needed.
NOTE: Areas where the film has been formed (corners, hems,
etc.) may require extra cleaning due to the proper-
ties of the film. Ensure that all protective film has been
removed from the fireplace prior to burning.