WARNINGS:
• TO AVOID FIRE, SHOCK OR DEATH; UNPLUG CORD OR TURN OFF POWER AT
CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
• To be installed and/or used in accordance with electrical codes and regulations.
• If you are not sure about any part of these instructions, consult an electrician.
Installation
WARNING: TO AVOID FIRE, SHOCK OR DEATH, unplug cord or turn off
power at circuit breaker or fuse and test that the power is off before wiring.
1.
Select size and type of round cord as per your requirements.
NOTE: Device will accommodate cords from 14/3 type SJ to 10/3
type S (0.36 in. to 0.72 in.) round cords.
2.
Loosen assembly screws and separate device body from housing.
3.
Back out clamp screws to remove strain relief insert if required.
NOTE: The strain relief will accommodate cords 0.36 in. to 0.43 in. with
strain relief insert installed, and from 0.43 in. to 0.72 in. with strain relief
insert removed.
4.
Feed wiring cord through housing.
5.
Strip cord jacket and each conductor insulation per the image below or as
per strip gauge printed on the side of plug/connector module.
Insulation
Isolant
Aislamiento
Cord Jacket
Gaine du cordon
Revestimiento del Cable
Rating and Lever Color
Rating
125V or 277V GR
Ground
GREEN ( )
Neutral
WHITE
Hot
BLACK
Hot
L7-15
Configurations
NOTE:
symbol denotes grounding.
PATENT STATEMENT
Patents covering this product, if any, can be found on leviton.com/patents
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada ULC to the attention of the Quality Assurance
Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
LIMITED 2 YEAR WARRANTY
For Leviton's limited 2 year product warranty, go to www.leviton.com. For a printed copy of the warranty, call 1-800-824-3005.
For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com
Lever Edge
15A and 20A Straight Blade, 15A Locking
®
INSTALLATION INSTRUCTIONS
0.63 in.
(1.58 cm)
0,63 po
(1,58 cm)
0.63 pulgadas
(1.58 cm)
Exposed Copper
Strands
Brins de cuivre
dénudés
Hilos de Cobre
Expuestos
1.5 in.
(3.81 cm)
1,5 po
(3,81 cm)
1.5 pulgadas
(3.81 cm)
250V GR
GREEN ( )
BLACK
BLACK
5-15
5-20
TM
Plugs and Connectors
CAUTIONS:
• Use this device WITH STRANDED COPPER WIRE ONLY.
• Wire size and type must comply with appropriate local electrical codes. In USA refer to
NEC tables article 400.
• Keep all levers in the closed position except when wiring the product.
6.
Connect wires.
a.
Fully open lever.
b.
Fully insert wire into proper wire well.
c.
Close lever and connect the remaining wires.
NOTE: Where applicable it is recommended to connect GROUND wire first.
CAUTION: Levers MUST contact on conductor only, NOT on insulation.
DO NOT USE SOLID WIRE. DO NOT TIN CONDUCTORS.
7.
Reattach the wired module to the housing by aligning key guide on the
module to the key on the housing, and tighten the assembly screws firmly
to 10-14 in.-Ib. torque. Firmly secure cord clamp on to housing by alternately
tightening cord clamp screws to 8-10 in.-lb. torque.
NOTE: Polarity of wiring for NEMA devices is identified by markings on
device and/or lever color as shown below.
Marking On Device
G, GRND, GREEN, or
N, Neutral or BLANK
X, Y, Z or BLANK
6-20
Aligning Key
Guide d'alignement
Clave de Alineación
Lever Color
GREEN - Grounding
WHITE - Neutral
BLACK - Hot
PK-A3516-10-02-0A-W
ENGLISH
Conductor Color
Bare, Green, or
Green/Yellow wire
White or Gray wire
Black, Red, Blue or any other
than White, Green, Gray,
Green/Yellow or Bare wire