KPX
WARNING!
If the suspension bracket
mounted on a conductive base which is connected to
the house installation or to earth, the suspension
bracket must also be connected to the potential con-
ductor. Total loss of function.
NOTICE!
The potential conductor may only be connected to the
cable reel by qualified personnel.
5.2. Mounting the supply line
1.
The cable cross-section of the supply line must be between 3 mm² and 4 mm²
2.
Remove the housing cover
3.
Feed cable Ø 7 - 11 mm through EX cable gland
4.
Strip 12 mm of insulation from the end of the supply cable (picture B)
5.
Connecting of the supply cable: open lever "Z" – feed in supply cable
(at least 11 mm) and close lever "Z" (picture C)
6.
Carry out strain relief
7.
Tighten the EX cable gland
Picture A
6
EFCO OPERATING INSTRUCTION
.
1
according to the sketches (pictures D)
7
until the seal kit tightly encloses the cable.
6
7
of the cable reel is not
2
(picture A).
6
Picture B
= 12 mm
Pictures D
Depending on the cable Ø, one or the other
side of the clamping part is used.
Cable Ø 7–9.5 mm
Picture C
Lever "Z"
Cable Ø 9.5 –11 mm
14