POSABLE INDUCTION / FREE STANDING INDUCTION
Device with ADV generttora
Keyboard Error
View
F3
Vitro temperature sensor in short circuit
F4
Vitro temperature sensor is cut or missing
F5
Electronic temperature sensor in short circuit.
(Power components)
F6
Electronic temperature sensor is cut or missing.
(Power components)
F7
Electronic power components overheating
F22
Vitro ceramic glass temperature overheating
F24
Electronic generator board overheating ambient temp.
F9
Fault lower main line voltage
F10
Fault higher main line voltage
F11
Temperature sensor on electronic board is missing or cut
F12
Temperature sensor on electronic board is in short circuit
F8-13
Fans are missing or out of order
F8-14
Fans are in short circuit
F8-15 / 16
Coil current mesurement problem (Ipp or Sync values)
F8-18
Voltage default (13,8V on generator board)
F19 / F20
Mainline frequency default (>maxi or <mini)
F8-27
Electronic default on generator board
F8-28
Wrong association of electronic board in the unit.
Configuration problem
F8-29
Hardware electronic security
F8-31
Communication default between keyboard and generator
board
Control/button
Abnormal power/temperature setting and off position of
malfunction
the control knob
Potential causes
ERROR CODES
Intervention / Operation
AFTER SALES DEPARTMENT
AFTER SALES DEPARTMENT
AFTER SALES DEPARTMENT
AFTER SALES DEPARTMENT
Let it cool and check that the device is well venti-
lated. If the error code is still present: Call customer
service.
Electrical network problem
Electrical network problem
AFTER SALES DEPARTMENT
AFTER SALES DEPARTMENT
FAN, AFTER SALES DEPARTMENT
FAN, AFTER SALES DEPARTMENT
AFTER SALES DEPARTMENT
AFTER SALES DEPARTMENT
Electrical installation problem
AFTER SALES DEPARTMENT
AFTER SALES DEPARTMENT
Press the ON / OFF key to acknowledge the fault
or disconnect / reconnect product. If error code
still present: Call After sales service.
AFTER SALES DEPARTMENT
Set the buttons to stop mode (white dot in up-
per position), then restart the mains supply.
22