PUMPS
GB
AQUA ACTIVE 1 2 V
bowl, tighten the union nut. Watch out! If you operate the pump in the filter bowl under
water, the skimmer must be connected to the inlet regulator or the inlet regulator
must be completely closed! To switch off the device, pull out the mains plug.
PUMP CONTROLLER
The pump controller displays the following values:
Power consumption PXXX in watts, power level FXXX, pause FEED.
To operate, use the three touch-sensitive buttons. Important here, the buttons do not
respond to touch pressure! When the pump controller is connected to the pump, the
last settings are automatically loaded. Touch the Start / Stop button to turn off the
pump. FEED appears in the display. Touch the Start / Stop button again to restart the
pump. During operation, the current power consumption in watts is shown on the display.
For example, P065 means 65 watts of instantaneous consumption. The capacity of the
pump can be regulated in 70 individual stages, from the lowest level F030 to the highest
level F100 where F stands for flow, English flow. Use the slow and fast keys to adjust the
power. After approx. 1 second, the display switches from the power level FXXX back to
the consumption display or wattage PXXX after pressing these buttons. If you do not
touch a button for more than 25 seconds, the display switches to standby mode. After
touching any key, the display is reactivated. To activate the lockout function so that the
pump power can not be accidentally adjusted, press the start / stop button during
operation until the display flashes three times and then release the button. Adjusting the
performance should no longer be possible. To unlock, press the Start / Stop button again
until the screen has fiddled three times.
Error codes pump controller
Er01: deviating operating current
Er02: Pump controller gets too hot
Er03: Pump is idling
Er04: Blockage of impeller
Er05: different operating voltage
CLEANING AND MAINTENANCE
Before every cleaning and maintenance, make sure that the device is switched off and
disconnected from the power source.
The filter housing and the running unit must be cleaned at regular intervals. The cleaning
interval depends heavily on the degree of contamination. The degree of pollution can vary
significantly from body of water to body of water. First open the filter basket and take
out the pump motor. To clean the rotor and the inner parts, additionally remove the
corresponding screws and pull off the cover of the motor housing. The rotor can then
be easily pulled out of the liner and cleaned. Do not use sharp-edged objects such as
brushes for cleaning. Steel brushes, use a soft sponge instead. Stubborn stains such as
PUMP CLEANSER
Limescale deposits are best removed with the premiumcare
10
pump cleaner. With sufficient flow, the pump is cooled by the water. Always make sure
that the pump works against as little resistance as possible. If the flow rate is reduced