Télécharger Imprimer la page

EUROM FRED 25/15 Manuel De L'utilisateur page 37

Publicité

Battery protection function
CAUTION
When the vehicle or vessel engine needs to be started, we recommend setting
the battery protection to high.
CAUTION
The device is measuring the voltage input of the device, not the voltage of the
vehicle or vessel battery.
CAUTION
When the battery voltage protection function shuts down the device error
code 'Er1' will appear on the display.
The battery protection function prevents draining the battery of the vehicle or vessel.
Battery voltage
protection
High
Med
Low
Power memory function
After restart, the temperature set will be the same with the one you set before switching off
the device.
After operation
CAUTION
1.
Switch off the device by pressing
2.
Remove all food and/or drinks.
3.
Clean the device inside and outside, see chapter Cleaning.
4.
Disconnect the power plug from the power outlet.
5.
Disconnect the power cable from the device.
6.
Wind the power cable.
12V stop
11,7±0.3V
10.7±0.3V
10.2±0.3V
Do not use the power cable to unplug or carry the device.
Do not wind the power cable too tightly or in sharp corners.
Do not wrap the power cable around the device.
12V start
12,7±0.3V
11,7±0.3V
11,2±0.3V
for 5 seconds.
24V stop
24.6±0.3V
22.6±0.3V
21.6±0.3V
24V start
26.0±0.3V
24.0±0.3V
23.0±0.3V