7.13 Connect the actuator distributor (L) to the actuator (A) of the electronic module (K).
7.14 Connect the electronic module (K) to the power supply.
Output
Actuator 1_1
Actuator 1_2
Temperature sensor 1
(for direct temperature
recording with the
electronic module)
Digital sensor input (2)
(for indirectly recording
temperature via an
external switching
contact)
8.
Maintenance and Servicing
Depending on the quality of the water, the local conditions and the rules and regula-
tions applicable on site, the fitting must be maintained and serviced at regular
intervals.
Use suitable cleaning agents that are not harmful to the fittings in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for
cleaning.
9.
Replacement Parts
Bezeichnung
Electronic module M1 . . . . . . . . . . . . 84-100-17.108
Surface sensor, red. . . . . . . . . . . . . . 2000100975
Description
Switching output for the heater of the water
reservoir ("storage filling") not floating, max. load
24 V DC, 1 A
Switching output for message "Temperature
reached", default logic "0", when the set tempe-
rature is reached logic "1", not floating, max. load
24 V DC, 1 A
Cyclical measurement of water-reservoir tempe-
rature
Connection for external temperature sensor
(logical input = 1 –> temperature reached) e. g.
computer-aided facility management via coupling
relay or immersion thermostat max. 20 m (1.5mm²
Cu)
Best.-Nr.
- 6 -