Addition to 6.2.1. Assembling the Parts Cleaning Device
We advise a two-man assembly to avoid damaging during the assembly of the IBS-Parts Cleaning Device Type M-500.
Remove the packaging.
Put in the two pedestals (1) into the tubular socket (located directly below the basin).
Fix the two cross braces (2) with the enclosed screws (M8x50) on the pedestals.
Fix the two diagonal braces (3) with the enclosed screws on the end with the frame (M8x50), other end with the rearward cross
brace (M8x20).
Place the 200 litre drum in the collecting tray (optional) with the screw connection facing upwards and remove the 2" sealing cap
from the body of the drum.
Place the assembled device on top of the drum.