LOCATION OF YOUR WASHER
Do Not Install the Washer:
1. In an area exposed to dripping water or outside
weather conditions. The ambient temperature
should never be below 60°F (15.6°C) for proper
washer operation.
2. In an area where it will come in contact with curtains
or drapes.
3. On carpet. The floor MUST be a hard surface with
a maximum slope of 1/2" per foot (1.27 cm per
30 cm). To make sure the washer does not vibrate
or move, you may have to reinforce the floor.
IMPORTANT:
Minimum Installation Clearances
• When installed in alcove: Sides, Rear,
Top = 0" (0 cm)
• When installed in closet: Sides, Rear,
Top = 0" (0 cm), Front = 1" (2.54 cm)
• Closet door ventilation openings required:
2 louvers each 60 square in. (387 cm
(7.6 cm) from top and bottom of door
Undercounter Installation
If an undercounter* installation is desired, you MUST
install a top sheet kit, 14-A037. This kit is available through
your GE retailer.
*Custom-sized countertop is required.
Mobile Home Installation
Installation must conform to Standard for Mobile Homes,
ANSI A119.1 and National Mobile Home Construction
and Safety Standards Act of 1974 (PL93-383).
Installation Instructions
), located 3"
2
ROUGH-IN DIMENSIONS
17
(43.2)
3 4
(1.9)
inch (cm)
36
(91.5)
Under
Counter
34
5 8
(87.9)
12
60
(152.4)
24
3 4
1
(62.9)
(2.54)
1
(3.81)
SIDE
Adjustable Legs
26
3
4
(67.9)
3
11
4
(29.8)
BACK
1 2
Power
Cord
33
1 2
(85)
7 8
2
(7.3)
Water
Inlets
31
5 8