– Take regular breaks and move your hands at the
same time to promote circulation.
Remaining risks
There will still be residual risks even when the device
is used according to the instructions and under obser-
vation of all of the safety notes in this set of operating
instructions:
• Touching the tool in the uncovered section.
• Reaching into the operating tool.
• Kickback from work pieces and work piece parts.
Personal protective clothing
Wear goggles when working with the device.
Wear ear defenders when working with the
device.
When working with tools that cause consid-
erable dust, wear a dust protection mask.
Do not wear protective gloves when working
with the device.
Wear tight fitting clothes when working with
the device.
If you have long hair, cover or wear a hair
net.
Your device at a glance
Note: The actual appearance of your prod-
uct may differ from the illustrations.
► P. 3, fig. 1
1. Speed controller
2. Locking button for continuous operation
3. On/Off switch
4. Shaving rejection chute
5. Foot plate
6. Switch for pendulum stroke
7. Saw blade
8. Locking screw for parallel stopper
Scope of delivery
• Jigsaw
• Saw blade (1×)
• Parallel stopper
• Vacuum adapter
• Allen key
• Operating instructions
Using for the first time
Fitting the saw blade
DANGER! Risk of injury! Pull out the
power plug before conducting any mainte-
nance work on the device.
WARNING! Risk of injury! Shortly after
sawing, the saw blade may be very hot. Risk
of burning! Allow a hot blade to cool down.
Never clean a hot saw blade with flammable
liquids.
CAUTION! Risk of injury! Even a saw
blade which is at a standstill can still cut!
Always wear gloves when replacing the saw
blade.
► P. 3, fig. 2
Suitable saw blades: ► P. 4, fig. 3, ► Technical
data – p. 31.
– Twist the locking sleeve (9) by 90° and hold.
– Place the saw blade (7) as far as it will go into the
holder.
– Release the locking sleeve (9).
– Ensure that the blade is securely fitted into place.
Operation
Check before switching on!
Check to make sure the unit is in a safe operating
condition:
– Check to make sure there are no visible defects.
– Check to make sure all unit components are cor-
rectly mounted.
Switching on and off
– Switching on: Press the On/Off button (3).
– Switching off: Release the On/Off switch.
– Permanent operation: Press the locking button
with the On/Off switch (2) held down.
– Set the required stroke rate with the rotating reg-
ulator (1).
Setting the cutting angle
The unit allows you to set a cutting angle of up to 45°.
► P. 4, fig. 4
– Loosen the screws (10).
– Swing the foot plate (5) into the required angle.
– Tighten the screws (10) back up again.
Setting the pendulum stroke
– Set the pendulum stroke with the switch (6):
– Switch setting [0] = Hard material
– Switch setting [1–3] = Soft material
Note: A higher pendulum stroke setting
increases the cutting speed, but may lead to
rougher cut edges.
Connecting the dust extraction mechanism
CAUTION! Risk of injury! When extracting
particular dangerous, carcinogenic or dry
dusts use a special extraction unit.
– Fit the suction hose of a suitable vacuum unit onto
the shaving rejection chute (4).
– If required, use the supplied adapter.
GB
29