EN
BATTERIES
Voltage of float
MODEL
charging
GEL
27.6V
Sealed
27.6V
Flooded
27.6V
User
27.6V
We strongly suggest to use 2× GEL batteries 12V, 18Ah, AGM (absorbent glass mat) type.
SOLAR PANEL
PARAMETERS
Model
Cells
Irradiance and Cell Temperature
Peak Power (Pmax)
Voltage at Pmax (Vmp)
Current at Pmax (Imp)
Open circuit Voltage (Voc)
Short-circuit Current (Isc)
Max number of panels for each controller
Operating temperature
Dimensions
Weight
2.4 - Charging mode
U
Equalized charge
Absorption charge
Bulk charge
24V
2.5 - Compatibility
The Solar Kit is compatible with the following 24V motors:
Sliding Gate Motors: SUN series 24V, TURBO series 24V
Swing Gate Motors: RAY series 24V, Star 200 24V, Star 500 24V,
REVO, MEWA 24V, UNDER 24V
Barriers: ALT series
2.6 - Consumption
It is possible to estimate the power consumption and thus the number
of maneuvers possible by the SOLE KIT, correlating the total system
power consumption and the power supplied by the batteries.
Below (see table pag. 6) are the standby power consumption of
devices that are commonly powered by the system.
To calculate the daily consumption of the system, follow the
installation example (Par. 2.7).
Dayly consumption is the sum of 4 factors:
1. A= consumption in stand-by mode when the gate is closed;
2. B= consumption when the gate is open and not in movement;
3. W= consumption when the gate is moving opening + closing;
4. NLS= activation of the Night Light System during night hours
(optional)
Dayly consumption= A+B+W+NLS
6
Voltage of
absorption
charging
28.4V
28.8V
29.2V
28.8V
Float charge
t
Time of
Voltage of
absorption
equalized
charging
charging
2h
--
2h
29.2V
2h
29.6V
2h
29.2V
900PF30W (SLP030- 24)
polycrystalline silicon solar cell
1000W/m² AM1.5 25°C
4 (parallel circuit)
675 x 357 x 23 mm
ATTENTION !
No equalized charging mode for GEL batteries.
ATTENTION !
For barriers ALT3/4/6 do not connect LED lights on boom
and disconnect double colour led discs on the barrier (only
possible to connect RED led with flashlight function).
See instruction of barrier control unit.
For the correct use of the kit, make sure that daily consumption does
not exceed the power supplied by solar panel.
Key Automation strongly suggest to use GEL batteries 12V, 18Ah,
AGM (absorbent glass mat) type.
ATTENTION !
Accessories will draw additional power from the battery; the
more accessories you connect, the more power your system
will require.
Time of
Interval of
equalized
equalized
charging
Charging
--
--
2h
28 day
2h
28 day
2h
28 day
VALUE
30W
34.4V
0.87A
43.2V
0.96A
-40+85°C
2,9 kg